Health Zenith SL-7001 Manual De Instrucciones página 2

Ocultar thumbs Ver también para SL-7001:
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

For proper operation, the sensor head must be
rotated face down as shown in the next two steps.
❒ Rotate the sensor head towards the clamp screw
joint.
Joint Clamp
Then rotate the sensor head clockwise 180° so
the controls face down.
❒ Plug the solar panel cable into the bottom of the
battery case. Allow the battery to charge with
three days of sunshine before testing.
TEST AND ADJUSTMENT
❒ Slide the sensor switch to
the TEST (center) position.
❒ Place the SENSITIVITY ad-
justment in the minimum
(counterclockwise) position.
NOTE: Sensor has a 1 minute warm up period before
it will detect motion. When switching modes
wait 1 minute.
❒ Loosen the clamp screw in
❒ Walk through the cover-
Control Switch
❒ Increase sensitivity only as
❒ Secure the sensor head
❒ After dark, adjust the light
Place the sensor switch in AUTO for normal opera-
tion. If the light is not needed, put the switch in the OFF
position.
• Objects that change temperature rapidly, such as
• Areas where pets or traffic may trigger the control.
• Nearby large, light-colored objects reflecting light
SENSITIVITY
TEST
OFF
AUTO
Bottom of Sensor
(2.4 m)
The detector is less sensitive to motion directly towards
it and more sensitive to across motion.
2
A
T
IMING
the sensor ball joint.
age area noting when the
lights turn on. Gently move
the sensor head up, down,
or sideways to change the
coverage area. Wait 5 to
10 seconds after light
turns off to retest.
needed. Too much sensi-
tivity will cause false trigger-
ing and reduce battery life.
into position by tighten-
ing the clamp screw. Do
not overtighten the screw.
to cover desired area.
Avoid aiming the control at:
heating vents and air conditioners. These heat
sources could cause false triggering.
may trigger the shut-off feature. Do not point other
lights at the sensor.
8 ft.
(15.2 m)
Maximum Range
Motion
Sensor
Least Sensitive
S
.
HE
ENSOR
Clamp
Screw
Ball
Joint
Aim Sensor Down
for Short Coverage
Aim Sensor Higher
for Long Coverage
100°
50 ft.
Maximum
Coverage Angle
Motion
Most Sensitive
595-5291-04
Tabla de contenido
loading

Tabla de contenido