Storage; Wiring Diagram - Dyna-Glo RMC-FA300DGD Manual De Instrucciones

Ocultar thumbs Ver también para RMC-FA300DGD:
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Dyna-Glo
ProFitter
& Dyna-Glo
Delux Operating Instructions and Parts Manual
Operating Instructions and Parts Manual
TM
TM
TM
Dyna-Glo
ProFitter
Propane Construction Heater
Maintenance (Continued)
Maintenance (Continued)
Fan
Fan
Setscrew
Setscrew
Motor Shaft
Motor Shaft
Hub
Hub
Figure 7 – Fan Cross Section
Figure 7 – Fan Cross Section
10. Reconnect lead wires as shown in
10. Reconnect lead wires as shown in
the Wiring Diagram (Figure 8).
the Wiring Diagram (Figure 8).
11. Reassemble base, fan guard and
11. Reassemble base, fan guard and
base lower.
base lower.

Wiring Diagram

Wiring Diagram
Figure 8 – Wiring Diagram
Figure 8 – Wiring Diagram
For Technical Support or Troubleshooting, Call: 1-877-447-4768
For Technical Support or Troubleshooting, Call: 1-877-447-4768, 8:30 am - 4:30 pm CST
& Dyna-Glo
TM
TM
IGNITOR
IGNITOR
The only maintenance necessary for
The only maintenance necessary for
the ignitor is to be sure that the gap
the ignitor is to be sure that the gap
between the electrodes is kept between
between the electrodes is kept between
.10" and .15". The ignitor is accessible
.10" and .15" (2.5. - 3.8 mm). The ignitor is
through the combustion chamber.
accessible through the combustion chamber.

Storage

Storage
propane tanks when not in use.
propane tanks when not in use.
1. Always store propane tanks in accor-
1. Always store propane tanks in accor-
dance with Chapter 5 of the Standard
dance with Chapter 5 of the Standard
for storage and handling of Liquefied
for storage and handling of Liquefied
Petroleum Gasses, ANSI/NFPA 58.
Petroleum Gasses, ANSI/NFPA 58.
Follow all local codes.
Follow all local codes.
Yellow
Gas
Solenoid
Valve
White
Valve
Chassis
Ground
White
Blue
Blue
Motor
Condenser
Motor
White
White
Thermostat
Thermostat
on / off
Black
Green
Line Cord
Power Cord
Green
Chassis
Ground
TM
Always disconnect
Always disconnect the
the heater from the
heater from the
High Limit
High Limit
Switch
Yellow
Switch
White
Back
Spark Plug
Back
Pressure
Pressure
Switch
Switch
Black
Black
Black
White
Line Seat
White
Yellow
Yellow
Green
Green
on / off
Black
Chassis
Ground
Ground
If any original wiring as supplied with the heater must be
replaced, it must be replaced with type AWG105°C wire or its
If any original wiring as supplied with the heater must be
equivalent except as indicated (∗Type SF2-200, ∗∗SGI-250°C)
replaced, it must be replaced with type AWG105°C wire or its
equivalent except as indicated (∗Type SF2-200, ∗∗SGI-250°C)
6
6
RMC-FA300PF/DG/DGD
NEVER LEAVE THE HEATER
UNATTENDED WHILE BURNING!
2. Replace the plastic caps over the
2. Replace the plastic caps over the
fittings that were installed when you
fittings that were installed when you
originally unpacked your heater.
originally unpacked your heater.
3. Store the heater in a safe, clean
3. Store the heater in a safe, clean
and dry location. Do not store the
and dry location. Do not store the
hose/regulator assembly inside the
hose/regulator assembly inside the
combustion chamber of the heater.
combustion chamber of the heater.
4. When removing the heater from
4. When removing the heater from
storage, always check inside of the
storage, always check inside of the
heater for any foreign objects left by
heater for any foreign objects left
spiders or small animals. Keep the
by spiders or small animals. Keep
inside of the heater clean from
the inside of the heater clean from
foreign objects and combustibles.
foreign objects and combustibles.
Spark Plug
Orange
Line
Line
Neut
Neut
Valve
Valve
Ground
Ground
PCB Assembly
Flame Control
www.ghpgroupinc.com
RMC-FA300DGD

Capítulos

Tabla de contenido
loading

Tabla de contenido