Siemens HE2224U Instrucciones De Instalación página 15

Ocultar thumbs Ver también para HE2224U:
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Four Wire Flexible Conduit Connec-
tion
Note:
DO NOT plug in range at this time.
1. Disconnect electrical power at the breaker box.
2. Remove the terminal block cover to expose the terminal block.
3. Remove the TOP nut, star washer, and round washer from each post.
Note:
DO NOT remove last round washer, last nut or internal wire leads.
4. Remove screw from bottom end of ground strap.
5. Remove ground strap from CENTER post. Discard ground strap.
6. Attach one terminal lug (included) through hole below terminal block using
ground screw.
7. Place one terminal lug (included) on each post. Replace the star washer and
round washer and secure with 20 inch pounds of torque.
8. Strip 3/8 inches (9.53 mm) of insulation from the end of each wire.
10. Insert the insulated grounding wire into the lug below the terminal block.
11. Insert stripped end of WHITE wire into the CENTER lug. Secure the clamping
screw.
lug
wire
13. Insert stripped end of RED wire into the LEFT lug. Secure clamping screw.
14. Insert BLACK wire into the RIGHT lug. Secure clamping screw.
15. Tighten each clamping screw with the appropriate torque. See Table 2.
Table 2: Appropriate Torque Levels for Aluminum or Copper Wire
Gauge
6
8
clamping screw
Figure 12: Attaching Wire to Terminal Lug
Torque (in./lbs.)
35
25
Installation
3/8 "
Figure 9: Wire Stripping
Torque (Nm)
3.95
2.82
English 11