While the engine is running, the charger checks the voltage the alternator is supplying to
Test alternator
the battery.
10. Alternator test running. Let engine run for approx. 30 seconds at 1500-2000 rpm
11. Charger displays alternator test result.
12. To finish the test, disconnect from battery/connect charger to mains supply to begin
Charging

General remarks

Charge battery

To start charging, proceed as follows:
1.
2.
3.
4.
5.
6.
7.
Conservation
The charger changes over automatically to conservation charging once the battery is
charging
fully charged. The charger continuously displays the fully charged symbol (4 bars).
Alternator voltage
Alternator voltage
O.K.
O.K. Possible
problems on short
journeys/in winter
charging.
Warning! Risk of explosion from short circuits and arcs. Before connecting to/
disconnecting from battery, disconnect charger from mains supply. During
operation, check that charging terminals and battery poles are properly con-
nected.
Caution! Risk of damage when attempting to charge a faulty battery. Before
charging, ensure that the battery to be charged is fully functional.
Switch off engine and ignition, shed all loads
Set selector switch to correct position
Establish connection to battery
Charger displays battery open circuit voltage
Connect charger to mains supply
Charger starts to charge
Charger displays current charge level as sequence of bars
0%
Alternator voltage
too low. Have
alternator checked
in workshop
20%
50%
4
Alternator voltage
too high. Have
alternator checked
in workshop
80%
100%