Displaying Min/Max/Avg, Ambient temperature,
Dew point temperature
3x
8
Dew point temperature
Dew point temperature is the temperature at which current air conditions
would produce condensation. The CondenseSpot calculates the dew
point temperature from ambient temperature, relative humidity and
ambient atmospheric pressure. In combination with the infrared ther-
mometer, thermal bridges are easily detected. If the temperature of the
measured location drops below the dew point, condensation (water)
will form on the surface.
IR-temperature
2.5 °C
than dew point temperature:
bar graph shows no indica-
tion. No condensation.
1x
=> MIN/MAX/AVG = 0
3 sec
5x
IR-temperature equal to
dew point temperature: bar
graph displays 5 segments.
Condensation begins.
CondenseSpot
2x
IR-temperature
dew point temperature: bar
graph displays 10 segments.
Condensation.
2.5 °C than