FOLLOW THESE STEPS WHEN BATTERY IS OUTSIDE VEHICLE
J.
A SPARK NEAR THE BATTERY MAY CAUSE BATTERY EXPLOSION. TO REDUCE RISK Of A SPARK NEAR BATTERY:
1.
Check polarity of battery posts. POSITIVE (POS, P,+)
battery post usually has a larger diameter than NEGA-
TIVE (NEG, N, -) post.
2.
Attach at least a 24-inch-long 6-gauge (AWG) insulated
battery cable to NEGATIVE (NEG, N, -) battery post (
not
provided).
3.
Connect POSITIVE (RED) charger clip to POSITIVE
(POS, P,+) post of battery.
4.
Position yourself and free end of cable as far away from
battery as possible - then connect NEGATIVE (BLACK)
charger clip to free end of cable.
5.
Do not face battery when making final connection.
6.
When disconnecting charger, always do so in reverse
sequence of connecting procedure and break first
connection while as far away from battery as practical.
7.
A marine (boat) battery must be removed and charged
on shore. To charge it on board requires equipment
specially designed for marine use.
K.
AC POWER CORD CONNECTION INSTRUCTIONS
DANGER - Never alter AC cord or plug provided - if it will not
fit outlet, have proper outlet installed by a qualified electri-
cian. Improper connection can result in a risk of an electric
shock.
L.
1.
These battery chargers are equipped with a self-
resetting circuit breaker. This device protects the charger
from temporary overloads. In the event of an overload,
the circuit breaker will trip open, and after a short
cooling off period will reset automatically. this process is
known as cycling and can be recognized by an audible
clicking sound.
M.
These chargers are for use with 12 volt lead-acid batteries
only.
N.
For smaller batteries, 30 AH (ampere hour) or less, use 2
AMP setting. Small batteries may not be able to accept the
potential of the 10 or 12 AMP setting. Unconverted energy will
result in excess heat which the battery may not be able to
dissipate, thus resulting in damage to the battery.
OPERATION INSTRUCTIONS
OUTPUT VOLTAGE
CHARGE RATE SWITCH
5
POSITIVE
BATTERY
24" 6 GAUGE
CABLE
FIGURE 8 CONNECT NEGATIVE BATTERY
CLIP TO 24 INCH CABLE END
This battery charger is for use on a nominal 120-volt
60 HZ circuit.
2.
These battery chargers are equipped with an electronic
control circuit which automatically governs the charge
rate to your battery. The charger will satisfactorily
charge Maintenance Free and Conventional batteries.
For larger batteries either setting may be used.
NEGATIVE
CHARGER
POWER
CORD
TO GROUNDED
POWER OUTLET