Technical Specifications - Urmet 1083/80 Guia Del Usuario

Ocultar thumbs Ver también para 1083/80:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

When the programming procedure has been performed, the relay is activated according to the position of
the jumper SCQ:
Position Q: the intercom call button of any system user activates the decoder.
Position C: the intercom call button of any system user in the column "Column ID" activates the
decoder.
Position S: the intercom call button of all apartment stations (also those in parallel) of the user in the
column "Column ID" and user code "CODE" (the one used to acquire the event) activates the decoder.
EVENT: PEDESTRIAN DOOR LOCK RELEASE COMMAND FROM SWITCHBOARD
Program the event by sending a pedestrian door lock release command from the switchboard (see paragraph
about events programming).
When the programming has been performed, the relay is activated each time a pedestrian door lock release
command is sent from the switchboard.
§
The position of dip-switches CODE and jumpers SCQ of special decoder is irrelevant for the operation
with pedestrian door lock release command from switchboard.
EVENT: DRIVEWAY DOOR LOCK RELEASE COMMAND FROM SWITCHBOARD
Program the event by sending a driveway door lock release command from the switchboard (see paragraph
about events programming).
When the programming has been performed, the relay is activated each time a driveway door lock release
command is sent from the switchboard.
§
The position of dip-switches CODE and jumpers SCQ of special decoder is irrelevant for the operation
with driveway door lock release command from switchboard.
EVENT: SPECIAL CODES COMMAND FROM CALL STATION OR SWITCHBOARD
Program the event by sending a special code "SPEC" from a call station or from the switchboard that must
activate the special decoder relay (see paragraph about events programming). The device from which the
special code is sent can be a secondary call station in the column number "Column ID", a main call station
or a switchboard.
When the programming has been performed, the following events will occur:
Sending of special code "SPEC" from the switchboard activates the decoder.
Sending of special code "SPEC" from a main call station activates the decoder.
Sending of special code "SPEC" from a secondary call station activates the decoder, according to the
position of jumper SCQ:
Position Q: Sending of special code "SPEC" from any secondary call stations activates the decoder.
Position C or S: Sending of special code "SPEC" from any secondary call stations in the column
"Column ID" activates the decoder.
§
The position of special decoder dip-switches CODE is irrelevant for the operation with special functions
buttons.
OPERATING MODE TO SIGNAL PANIC ALARM TO SWITCHBOARD (DIP1 = ON)
§
This function can be used in systems provided with concierge switchboard with software version 3.1
or higher.
In this operating mode the special decoder must be programmed as follows:
1 – Move the dip-switch 1 in position ON
2 – Assign to the special decoder a user code from 0 to 127 using dip-switches CODE
§
To set the desired code use dip-switches from 2 to 8 (2 = most signifi cant bit – 8 = least signifi cant
bit).
The user code can be the same used in apartment stations of the same apartment.
When the programming has been performed, by pressing the remote button (PC) a panic alarm is sent to
14
the switchboard, with indication of the column where the decoder is installed and the programmed user
code (CODE).
At the same time the relay is activated, according to the confi gurations of the toggling mode.

TECHNICAL SPECIFICATIONS

Power supply voltage: ...................................................................................................................36 ÷ 48Vdc
Current consumption in standby: ................................................................................................. 3,0mA max
Max. current consumption: ........................................................................................................... 30mA max
Operating temperature range: ............................................................................................... - 10°C ÷ + 50°C
Compliant with: ............................................................................................... EN 61000-6-3, EN 61000-6-1
C-NC-NA contact switching: ........................................................................................................... 30Vdc 5A
DS1083-019A
DS1083-019A
250Vac 5A
15
Tabla de contenido
loading

Tabla de contenido