6 Operation
The measuring sleeves are torch-specific and have different threaded stems:
M8
M6
M10
M7
M10x1
Tab. 6
1 Screw in the measuring sleeve (12) at the position of the contact tip.
2 Plug on/screw in the adjusting sleeve (13) at the position of the gas nozzle.
6 Operation
NOTE
Before inserting the torch into the alignment jig, check:
• whether the correct interface and the corresponding torch are inserted.
• whether the dust and welding spatters are removed. This might cause wear and reduced test
6.1 Quick Control
1 Remove the neck liner and the wire guide.
2 Fasten the change neck torch into the clamping device.
1
Fig. 3
3 Move the test madrel (1) to the contact tip (2).
The bending angle is correct if the tip of the test mandrel (1) and the contact tip (2) are centered.
6.1.1 Check the alignment.
1 Unscrew or pull out the gas nozzle and remove other torch-specific fittings.
1
Fig. 4
2 Screw in the measuring sleeve (2) at the position of the contact tip.
The bending angle is correct if the test mandrel (1) fits easily into the bore of the measuring sleeve (2).
EN - 8
WH 455, WH 505/505 TS, ROBO VTS 0/500 TS, ABIROB
WH 241/242, ROBO VTS 500/500 TS, ROBO VTS 290,
WH 650/652
WH cold wire / laser
ABIROB
Adjusting sleeves
accuracy.
1
Test mandrel
Quick Control
1
Test mandrel
Checking the Alignment
®
350 GC
2
2
Contact tip
2
2
Measuring sleeve
Alignment jig
®
W 500 TS