Fault
Possible cause
Jamming nails
Damaged driver assembly
The driver blade is stuck
in the bottom position
Material and nail length not suitable.
Nail debris in the nosepiece
Depth set too low.
Device not placed firmly against the
workpiece.
Material and nail length not suitable.
Nails are not driven fully
home
Damaged or worn driver blade.
Device used with protective cap
Damaged trigger mechanism
No nails in the magazine
Incorrect size or nail
Nail debris in the nosepiece
Nail is not driven in.
Worn magazine
Damaged or worn driver blade.
Incorrect size or nail
The screws in the magazine have not been
tightened after the preceding dust removal/
inspection.
Damaged or worn driver blade.
Jamming nails
Material and nail length not suitable.
Nail debris in the nosepiece
Worn magazine
The safety catch has been activated and
the user is applying excessive force to the
contact stop so that the catch is overridden.
Remedy
Remove the jammed nail and manually pull the driver blade back,
if necessary.
Contact an authorised Würth customer service centre.
If the device continues to jam, select the right nail length for your
application.
Remove all pieces of broken nails and clean the nosepiece.
Turn the depth adjustment wheel to a deeper setting.
Apply sufficient pressure to the device.
If the device continues to jam, select the right nail length for your
application.
Contact an authorised Würth customer service centre.
Remove protective cap
Contact an authorised Würth customer service centre.
Ensure that there are sufficient nails in the magazine.
Use only the recommended nails.
Remove all pieces of broken nails and clean the nosepiece.
Contact an authorised Würth customer service centre.
Contact an authorised Würth customer service centre.
Use only the recommended nails.
Ensure that the Allen screws on the magazine are securely tight-
ened using the Allen key supplied.
Contact an authorised Würth customer service centre.
If the device continues to jam, select the right nail length for your
application.
Remove all pieces of broken nails and clean the nosepiece.
Contact an authorised Würth customer service centre.
Load nails into the magazine to deactivate the safety catch.