4.1) Moving blade
Make sure that the ram is completely retracted. If this is not the case follow the instructions
described in § 2.4.
With Allen keys provided, remove security grub screw (14) and slacken grub screw (13) until the
blade is free.
Remove the old blade from the head.
Fully insert the new blade (7). Ensure that the short side of the blade is positioned at the front
of the head as illustrated in Figure.
Fully tighten grub screw (13) and fit the security grub screw (14).
4.2) Fixed blade (B-TD410T)
With 4 mm Allen key, remove screw (16) until the blade is free to be removed.
Fully insert the new blade (5) and secure with the fixing screw (16) and washer (15).
13
14
5. CONNECTION TO COMPUTER
9
7
The memory card integrated in the tool records operating data from
200.000 cycles for transfer via the USB cable supplied.
To view and manage this data, go to www.cembre.com and register in
the dedicated area, then download the free Cembre software
CEM_SWBT01. Keeping the Firmware of the tool updated, via free of
charge download from here, will optimise the tool's performance.