Tools Required
Philips screwdriver, Torx T-20 bit (included), 6mm multi-bit
screw driver or 6mm socket, 1/4" drill bit. Quick mount can
accommodate #8 bolts (5/32") maximum.
Installation
1.
Remove the junction box mounting plate from the top
of the fixture by loosening one side screw and sliding
the fixture plate out from the holding brackets on the
top of the casting.
2.
Install the mounting plate to the junction box with two
screws (not provided). The bracket should be positioned
to allow the fixture to be "square" with the sides of the
canopy the fixture is mounted to.
3.
Hang the fixture from support spring while wiring the
unit. Bring the fixture input wires from the top of the
fixture and connect to the power leads in the junction
box – black to black (hot), white to white (neutral), and
green to green (ground).
4.
Connect the main housing to the junction box bracket.
Hold in place while reinstalling one side locking screw.
5.
Turn on the power. The fixture will come to full output
in several seconds.
N
ote:
Do not remove the bottom lens or touch the LED
optics. All LEDs are preinstalled and ready to
operate.
N
ote:
To weatherproof your outdoor installation, all gaskets
must be seated properly and all screws inserted and
tightened firmly. Apply weatherproof silicone sealant
around all edges between the fixture housing and
mounting surface.
Pendant Mounting
1.
Remove the rubber plug from the top of the fixture
using pliers or a flat head screwdriver. Take precaution
not to strip the inner threading. Feed remaining length
of wire through the plug and discard plug.
2.
Feed input leads through a 6" x 3/4" threaded conduit
pipe (not supplied), apply RTV silicone between
threads, and screw conduit pipe into fixture threading.
3.
Apply RTV silicone at joint between fixture and pipe.
4.
Attach fixture with conduit pipe to the junction box.
5.
Bring the fixture input wires from conduit pipe and
connect to the power leads in the junction box black to
black (hot), white to white (neutral), and green to green
(ground).
6.
Reconnect power at circuit breaker and test fixture. Full
output should occur within seconds.
N
ote:
Do not remove the bottom lens or touch the LED
optics. All LEDs are preinstalled and ready to
operate.