Method of functioning
The device has a combustion drive with explosive
gas mix. By ignition of the gas mix, the piston is
actuated and drives in the fasteners. Exhaust gas
and noise emissions, which may be hazardous to
health, are generated during the combustion pro-
cess. Adhere to the stipulated safety instructions.
Battery and charger (fig. II)
Charge the battery
The battery must be charged for 24 hours prior to
first use and when it has not been in use for a longer
period of time to achieve full capacity.
To remove the battery [5] from the device, fully
■
push the two release buttons [6].
Plug the power plug into the socket and the
■
charging plug into the socket of the charger.
3 The charging process starts as soon as the
battery [5] is set in the charging cradle. The
battery warms up during charging. This is a
normal process.
Indications
The charger is equipped with red and green LED
indicators
that show the charging state:
Green LED illuminates:
■
3 Charger is ready to operate. The battery is fully
charged.
Red LED illuminated:
■
3 The charging process is activated. The battery is
being charged.
Red and green LED flash in turn:
■
3 Temperature fault; battery is too hot and cannot
be charged.
• Remove the battery and allow it to cool
down.
Red and green LED flash simultaneously:
■
3 Charging not possible; battery defective.
• Replace battery.
Battery charging state / maintenance
indication
The indication [4] on the device allows monitoring
of the battery charging state and indicates if mainte-
nance is needed.
It illuminates in red if the battery needs to be
■
charged.
It flashes in red if the device must be sent to
■
Würth masterService for maintenance.
34
Gas cartridge (fig. III)
Attaching the dosing valve
For the exact dosing of the gas mixture required for
the combustion process, the supplied dosing valve
must be attached onto the gas cartridge. Only this
dosing valve guarantees a precise dosing of the gas
mixture and the contact pressure resulting therefrom.
1. Push the protective cap [17] for-
ward and remove it.
17
2. Remove the protective cap.
3. Attach the dosing valve [18] onto
18
the nozzle of the gas cartridge [19]
and allow it to engage into the front
19
groove. Do not point outlet opening of
the dosing valve at the face or eyes!
6. Press the dosing valve on the rear
part downwards until it audibly enga-
ges (2 clicking sounds).
Warning
Remove the dosing valve [18] prior
to transport and storage and put it on
again together with the protective cap.
Inserting the gas cartridge
Warning
Remove the batter from the device
before inserting the gas cartridge.
Press on the cover of the intake slot
1
2
■
upwards at an angle and fold this out
Attention!
Ensure that the metering valve of the
fuel cell is green.
Insert the gas cartridge with the valve head
3
■
facing the intake slot.
Ensure that the nozzle of the dosing valve
■
latches in to the small green adapter.
Close the cover.
4
■