INSTALLATION
Make the connections as shown in Fig. 1 (RX) and Fig. 2 (TX). Secure and power the photocell
(12 - 24 V DC/AC.
The photocell is set up to operate in synchronised mode. In this mode, the photocells will only
work if powered with alternating current. When making the connections, pay attention to the exact
position of the cables A and B (Fig. 3).
Cover the photocell with the front panel and secure it with the screws provided. Interrupt the photocell
beam several times to check proper relay response.
JUMPER FUNCTIONS:
J3 (RX)
CLOSED = Standard operation
OPEN = Delayed operation, to be used in particular weather conditions (snow).
N.B.: Delayed operation must not be set with the synchronism.
J5 = A B: N.C. output contact
J5 = B C: N.O. output contact