Air4 Universal Receiver
2. Consult the manual of the original system to identify the terminals relating to the power supply
and the appropriate relay contacts. The load connected to the relay contacts must be connected
with the appropriate precautions against fire and electric shock respecting the maximum load
values imposed 3A (230 Vac).
3. Connect 2 suitable wires to the power supply terminals (Fig.1- F) on the Universal Receiver and 2
wires to either the relay terminal 1 or the relay 2 terminals (Fig.1- H; G).
4. Connect the 4 wires in parallel to the appropriate terminals on the existing electronic board.
Consult the original manual if necessary.
THE POLARITY INDICATED
ON THE EXISTING RECEIVER
AIR4 UNIVERSAL RECEIVER POWER SUPPLY TERMINALS
ARE WITHOUT POLARITY POWER SUPPLY + CAN BE
CONNECTED TO EITHER TERMINAL,
Note: Make sure the receiver antenna wire is not twisted and/or bent; to ensure the best signal it
must be as straight as possible.
5. Your gate, overhead door or barrier is now ready for opening and closing with your Silca remote
control.
Switch on the power supply. The Silca Air4 Universal Receiver is now ready to work.
IS MERELY INDICATIVE.
POWER SUPPLY
12/24V
RELAY 1
AT THE USER'S DISCRETION
Copyright Silca S.p.A 2020. All right reserved
EXISTING AUTOMATION
ELECTRONIC CARD
-
+
AIR4 UNIVERSAL
RECEIVER
FIG.4
E n g l i s h
FROM EXISTING
GATE SYSTEM
RELAY 2
RELAY 2
ANTENNA
5