Honda EU22i Manual De Explicaciones página 47

Ocultar thumbs Ver también para EU22i:
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

3. Connect the red lead of the battery charging cable to the positive (+)
battery terminal and the black lead to the negative (–) battery
terminal.
YELLOW INDICATOR
OFF
ON
4. Start the generator (see page 28).
Do not start the vehicle while the battery charging cable is connected
and the generator is running. The vehicle or the generator may be
damaged.
An overloaded DC circuit, excessive current draw by the battery, or a
wiring problem will trip the DC circuit protector (PUSH button extends
out). If this happens, wait a few minutes before pushing in the circuit
protector to resume operation. If the DC circuit protector continues to
go OFF, discontinue charging and see your authorized Honda
generator dealer. The circuit protector does not prevent overcharging
the battery.
PUSH
DC CIRCUIT
PROTECTOR
BATTERY CHARGING CABLE
(Optional equipment)
DC RECEPTACLE
OPERATION
BLACK LEAD
RED LEAD
43

Capítulos

Tabla de contenido
loading

Tabla de contenido