Mini Kinta™ QRG
DMX Linking
Starting Address
Master/Slave
Connection
DMX Values
3-CH
Channel
The Mini Kinta™ can work with a DMX controller when linked by DMX
serial connections. Instructions for connecting and configuring this product
for DMX operation are in the User Manual. If you are not familiar with
DMX, download the DMX Primer from www.chauvetlighting.com.
To ensure full access to all channels in each DMX mode, the highest
recommended DMX address is 510.
The Mini Kinta™ uses the DMX data connection for its Master/Slave mode.
Instructions for connecting and configuring this product for Master/Slave
operation are in the User Manual.
Function
Control/
1
Operating Mode
2
Strobe
3
Motor Rotation
Value
Percent/Setting
000 005 No function
006 020 Red
021 035 Green
036 050 Blue
051 065 White
066 080 Red/Green
081 095 Red/Blue
096 110 Red/White
111 125 Green/Blue
126 140 Green/White
141 155 Blue/White
156 170 Red/Green/Blue
171 185 Red/Green/White
186 200 Green/Blue/White
201 215 Red/Green/Blue/White
216 230 Automatic (4-color chase)
231 255 Automatic (7-color chase)
000 005 No strobe
006 255 Strobe (slow to fast)
000
No function
001 127 Motor indexing
128 255 Motor speed
5