5.2 - REPLACING THE COIL
• Loosen the screw (or nut) or remove the Seeger ring (1) that locks the coil (2) and take it out from the armature assembly
along with the gaskets/discs;
• Place the new coil + gaskets + discs inside the armature assembly and secure with the relative screw (or nut or Seeger ring);
6.0 - CPI SWITCH / OPI SWITCH
The microswitch that signals the closed position (CPI SWITCH) is a magnetic proximity sensor with normally open contact. It
provides a signal when the valve obturator closes.
If the solenoid valve comes with the CPI, the position of the sensor is already calibrated and set, therefore, for operation you
simply need to connect it to the power supply.
If it comes separately and is installed at a later time on a solenoid valve with CPI set-up, follow the instructions provided in
paragraph 6.2 in the CPI instruction manual.
While the OPI SWITCH provides a warning when the valve is open.
The table on the next page shows the feasibility of CPI/OPI in relation to diameters.
For CPI and OPI technical features, see the relative instruction manuals.
Max P.
DN
(bar)
15-20-25
0.36
15-20-25
1-3-6
32-40-50
1-3-6
7.0 - TRANSPORT, STORAGE AND DISPOSAL
• During transport the material needs to be handled with care, avoiding any impact or vibrations to the device;
• If the product has any surface treatments (e.g. painting, cataphoresis, etc), it must not be damaged during transport;
• The transport and storage temperatures must observe the values provided on the rating plate;
• If the device is not installed immediately after delivery, it must be correctly placed in storage in a dry and clean place;
• In humid facilities, it is necessary to use driers or heating to avoid condensation.
• At the end of its service life, the product must be disposed of in compliance with the legislation in force in the country where
this operation is performed.
8.0 - WARRANTY
The warranty conditions agreed with the manufacturer at the time of the supply apply.
Damage caused by:
• Misuse of the device;
• Failure to comply with the requirements set out in this document;
• Failure to observe the regulations pertaining to installation;
the rights of the warranty or compensation for damage cannot be claimed.
The warranty also excludes maintenance work, the assembly of parts or non-original spare parts, making changes to the
device and natural wear.
Madas Technical Manual - 1|1.7J - REV. 0 of 1
CPI/OPI feasibility
Set-up
CPI
OPI and CPI+OPI versions can only be supplied from the factory.
For these 2 versions, the version with set-up is not envisaged.
Aug 2019
st
CPI
15
JVAP/NA - JVAP-1-3-6/NA - JVA-1-3-6/NA
OPI
CPI + OPI