Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 5
4BAR Tri™ QRG

Menu Options

Main Level
DMX Mode
Sound Active Mode
Automatic Mode
DMX Linking
Starting Address
Master/Slave
Connection
DMX Values
15-CH
Channel Function
Programming Levels
512
SND
AUTO
The 4BAR™ Tri can work with a DMX controller when linked by DMX
serial connections. Instructions for DMX operation are in the User Manual. A
DMX Primer is available from www.chauvetlighting.com.
To ensure full access to all channels in each DMX mode, the highest
recommended DMX address is 498.
The 4BAR™ Tri uses the DMX data connection for its Master/Slave mode.
Instructions for connecting and configuring this product for Master/Slave
operation are in the User Manual.
Control/Operating
1
Mode
2
Dimmer
3
Strobe
4
Red
5
Green
6
Blue
7
Red
8
Green
9
Blue
10
Red
11
Green
12
Blue
13
Red
14
Green
15
Blue
d 1-d512
Sets DMX starting address
S 1-S100
Sets Sound Active mode and sensitivity
S 1-S100
Sets Auto Program and speed
Value
Percent/Setting
000  009 RGB Color Mixing
010  029 Auto Program 1
030  049 Auto Program 2
050  069 Auto Program 3
070  089 Auto Program 4
090  109 Auto Program 5
110  129 Auto Program 6
130  149 Auto Program 7
150  169 Auto Program 8
170  189 Auto Program 9
190  209 Auto Program 10
210  229 Auto Program 11
230  249 Auto Program 12
250  255 Sound-Active mode
000  009 No function
010  255 Dimmer 1~100%
000  009 No function
010  255 Slow to fast
000  255 0~100%
000  255 0~100%
000  255 0~100%
000  255 0~100%
000  255 0~100%
000  255 0~100%
000  255 0~100%
000  255 0~100%
000  255 0~100%
000  255 0~100%
000  255 0~100%
000  255 0~100%
4
Description
RGB Color Mixing
(Pod 1)
RGB Color Mixing
(Pod 2)
RGB Color Mixing
(Pod 3)
RGB Color Mixing
(Pod 4)
EN
Tabla de contenido
loading

Este manual también es adecuado para:

4bar

Tabla de contenido