Led Diagnostics And Acoustic Signals; Stihl Ar Backpack Battery; Battery Status; Power Tool Status - Stihl HSA 94 R Manual De Instrucciones

Ocultar thumbs Ver también para HSA 94 R:
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

English
► Remove the AP Adapter from the charger and disconnect
the charger's power supply cord from the wall outlet when
charging is complete.
► Charge STIHL AR backpack batteries only with genuine
STIHL AL 300 or AL 500 series chargers.
To charge an AP battery:
2
1
► Push the battery (2) into the charger (3) until it stops.
The LED on the charger glows green when the battery is
charging.
The LEDs (1) on the battery glow green and show the
state of charge.
When the LEDs on the battery go out, the charging
process is complete and the charger will shut itself off.
► Remove the battery from the charger and disconnect the
charger's power supply cord from the wall outlet.
► Charge STIHL AP series batteries only with genuine
STIHL AL 101, AL 300 or AL 500 series chargers.

11 LED Diagnostics and Acoustic Signals

11.1 STIHL AR Backpack Battery

11.1.1 Battery Status

Six LEDs and an acoustic signal indicate the status of the
battery.
20
3
4
11 LED Diagnostics and Acoustic Signals
1
2
3
1 A short beep
The acoustic signal works as it should.
2 Four long beeps
The battery's charge is low. Recharge the battery.
3 Rapid succession of short beeps
There is a malfunction in the battery. The signal stops
automatically after a few seconds. Do not attempt to
charge, use or store the battery. Replace the battery.
These LEDs can glow or flash green or red.
If one LED glows red continuously: the battery is
either too hot or too cold. Allow the battery to
warm up or cool down gradually at an ambient
temperature of about 50 °F to 68 °F (10 °C to
20 °C).
If the four right side LEDs flash red and a rapid
succession of several short beeps is emitted: the
battery has a malfunction and must be replaced.
Do not attempt to charge, use or store the
battery.
► Be aware that your ability to hear the acoustic signal may
be reduced when wearing hearing protection.

11.1.2 Power Tool Status

When the battery is connected to the power tool, the same
LEDs on the battery will indicate the status of the power tool.
.......
0458-722-8621-A

Capítulos

Tabla de contenido
loading

Este manual también es adecuado para:

Hsa 94 t

Tabla de contenido