Safety rules
•
The personnel carrying out the installation, commis-
sioning, maintenance or repair of the device must be
properly qualified for this type of work. In particular,
the persons concerned must
- be suitably trained and familiar with handling
compressed-air systems besides being informed
about the associated dangers,
- know the content of the relevant instructions for
installation and operation, and
- possess vocational qualifications or entitlements
in this particular field of work.
•
Before the start of any work, the housing must first
be depressurized.
•
To ensure safe functioning, only use the device within
the operational limits (operating pressure, operating
temperature, volumetric flow, material stability).
•
As regards the model including a manual outlet valve
(needle valve), an additional diaphragm is installed
at the outlet side so as not to produce a sudden
pressure drop when opening and not to endanger
persons or other devices. The operator of the plant
assumes responsibility for the condensate discharge
which must be effected on a regular basis. In the case
of non-compliance, other plant components may be
damaged by condensate.
•
In the event of leaks, shut off the compressed-air
supply immediately and eliminate the cause in order
to maintain safe and cost-effective operation.
•
CLEARPOINT
filters, including accessories, must
®
be checked once a week. This applies in particular
to the function of the separator.
•
For connections or joints only use suitably threaded
fittings designed for this pressure range, see
page18, 20, 22.
CLEARPOINT HP 100 S040-M020, HP 350 S030-M015, HP 500 S030-S050
english
Areas of application of filter
CLEARPOINT
filters are designed for the separation
®
of solid particles, aerosols, oil vapours and odours from
non-aggressive compressed air or industrial gases. De-
pending on the specific application, the filter housings
are provided with different inserts:
C Coarse filter for the separation of coarse solid matter
pollutants up to 25 µm.
G General purpose filter element for the separation of
large dirt particles up to 5 µm.
F
Fine filter element for the separation of liquids up to
0.1 mg/m³ and solid particles up to 1 µm.
S Super fine filter element for the separation of liquids
up to 0.01 mg/m³ and solid particles up to 0.01 µm.
N Nano filter element for the separation of liquids up
to 0.005 mg/m³ and solid particles up to 0.01 µm.
A Activated carbon filter elements for the separation
of oil vapours up to 0.003 mg/m³ and odours.
R(x) Dust filters for the separation of particles, fineness
from C to N
Limits in usage: see Technical data, page 18, 20,
22.