Application Overview - DEVI DEVIheat 100S Guia De Instalacion

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 18
Installation Guide
3
Installation guidelines
• It is not recommended to install thin mats
at temperatures below –5 °C.
• The subfloor construction must be
secure to avoid relative movement after
installation.
• Prepare the installation site properly by
removing sharp objects, dirt, etc.
• If walking on the elements is necessary
during installation and carefully purring
of screed, only use soft shoes.
• Be careful not to damage the thin mat
with sharp tools, shovel, bucket etc.
• Minimum distance between heating ca-
bles; heating cable and conductive parts;
heating cable and other heating sources
such as hot water pipes and chimneys,
must be at least 50 mm.
• Heating cables may not touch or cross
themselves or other heating cables.
• Heating cable bending diameter must be
at least 6 times cable diameter.
• The thin mats are not to be installed on
irregular surfaces.
• The thin mat must be fully embedded in
screed (fine concrete).
• Do not lay thin mats under walls and
fixed obstacles.
4

Application overview

The thin mats listed below all are for floor
heating and comply with the EN/IEC
60335-1 standard + EN/IEC 60335-2-96.
5
Warranty
A 20 year full service warranty is valid for
DEVI thin mats and cables.
The DEVIwarranty™ is granted to:
Address
Product
Laying out Date
& Signature
Connection Date
& Signature
DEVI
Thin mats
• Do not place objects that will cause a
• The flooring must not have a thermal
• Keep thin mats clear of insulation material,
• Position the thin mat so that it is at least
• Thin mats must always be in good contact
• Always roll out thin mats with the heating
• Ensure not to crease the thin mat.
• If additional securing is required hot melt
• When the thin mat reaches the area
• The thin mat and especially the con-
• Free end from cold lead must be pro-
• DEVIheat™ 100S/150S
• DEVIcomfort™ 100T/ 150T
• DEVImat™ 70T/100T/150T/200T
For full warranty text visit www.devi.com,
devi.danfoss.com/en/warranty/
Art. No.
Resistance [Ω]
Resistance [Ω]
VIJUA302
thermal block e.g. furniture, thick carpets,
etc. Min. 6 cm air space is required.
insulation value of more than
R < 0.18 m2K/W corresponding to 1.8 Tog.
other heating sources and expansion joints.
half the C-C distance from obstacles.
with the heat distributor (e.g. concrete).
cables facing up.
glue, double adhesive tape or tile glue
can be used.
boundary, cut the liner/net and turn the
mat before rolling it back. Do not cut the
heating cable.
nection must be protected from stress
and strain.
tected by installer to avoid water from
coming in.
Resistance [Ω]
Insulation [MΩ]
Insulation [MΩ]
EN
Stamp
5