Uline H -7241 Manual Del Usuario página 7

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

REPLACING THE BLADE
Make sure to disconnect from
the power supply.
1. Turn the locking knob
clockwise to unlock the top
sealing unit. (See Figure 8)
2. Open the top sealing unit.
(See Figure 9)
3. Pull the blade to the right
side. (See Figure 10)
CAUTION! Sharp blade.
4. Take the blade out of the
machine and insert a new
one. (See Figure 11)
5. Turn the locking knob
counterclockwise to re-lock
the top sealing unit.
PAGE 7 OF 27
MAINTENANCE
Figure 8
Figure 9
Figure 10
Blade
Figure 11
Blade
CHANGING THE BELTS
1. Remove the blue covers on
both the top and bottom
sealing units using included
Allen key. Ensure the top
sealing unit is unlocked.
(See Figure 12)
2. Push the top sealing unit to
the left.
3. Remove the Teflon
®
while applying upward
pressure to the top sealing
unit and replace with a new
Teflon
belt. (See Figure 13)
®
4. Repeat steps 2 and 3 with
the bottom sealing unit.
5. Reattach the blue covers
using the included Allen key
and turn the locking knob
counterclockwise to lock
the top sealing unit.
(See Figure 14)
NOTE: Visit uline.com
to order replacement
injector blades (H-7241-
INJCT) and teflon belts
(H-7241-TBELT).
Figure 12
belt
Figure 13
Teflon Belt
Figure 14
0621 IH-7241
Tabla de contenido
loading

Tabla de contenido