5.6

Securing the burner to the boiler

Provide an adequate lifting system of the burner.
To install the burner on the boiler, do the following:
 if necessary, widen the holes of the insulating gasket
(Fig. 8), taking care not to damage it.
The burner can be fixed with the variable position (A) as shown
in Fig. 9.
Model
RS5F
 Fix the flange 5) to the door of the boiler 1)(Fig. 10) placing
the insulating gasket 3) in between using the screws 4) and (if
necessary) the nuts 2), but keeping one of the two top
screws 4) loose.
 Insert the combustion head of the burner in the flange 5),
tighten the flange with the screw 6), then lock the screw 4)
which was loose.
In any event, make sure that the combustion head
crosses the entire thickness of the boiler door.
ATTENTION
The seal between burner and boiler must be
airtight.
ATTENTION
Installation
A (mm)
225 203
Tab. H
SW1003
15
D5012
GB
Fig. 8
A
D6341
Fig. 9
Fig. 10
20141167