Troubleshooting (cont.)
Faucet Troubleshooting Table
Symptoms
2.
Low water flow.
3.
Poor spray
pattern.
4.
Power LED is not
lit.
1318209-2-A
Probable Causes
Recommended Action
D. The outlet
D. Confirm that the
hose is
solenoid valve is
kinked.
located within 7" (178
mm) to 8" (203 mm) of
the faucet centerline.
E. Refer to the "Cleaning
E. One or more
screens are
the Screens" section.
clogged.
A. The supply
A. Confirm that the
stops are
supply stops are fully
partially
open.
closed.
B. Handle is
B. Rotate the handle to the
partially
full open position.
closed.
C. The hot
C. Confirm that the
and/or cold
supply hoses are not
supply hose
kinked or twisted. If
is kinked or
coiled, maintain an ID
twisted.
of 3" (76 mm).
D. The outlet
D. Confirm that the
hose is
solenoid valve is
kinked.
located within 7" (178
mm) to 8" (203 mm) of
the faucet centerline.
E. Refer to the "Cleaning
E. One or more
screens are
the Screens" section.
clogged.
F.
Cracked
F.
Replace the solenoid
diaphragm.
valve assembly.
A. The spray
A. Rub your finger over
nozzles are
the nozzles with water
clogged.
running to dislodge
debris.
A. No power to
A. Check the power
the circuit
supply connections to
board.
the circuit board.
18
Kohler Co.