Electrical Installation; Operation; Before First Start-Up Break-In Procedure; Operating Procedure - Campbell Hausfeld HU350899 Manual De Instrucciones Y Lista De Piezas

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Installation
LOCATION
It is extremely important to install the compressor in a clean,
dry, and well ventilated area. The compressor must be placed
on a firm, level surface where the surrounding air temperature
will not be more than 100°F.
A minimum clearance of 18 inches between the compressor
and a wall is required because objects could obstruct air flow.
Do not locate the
compressor air inlet near steam, paint
spray, sandblast areas or any other source of contamination.
This debris will damage the motor.

ELECTRICAL INSTALLATION

All wiring
and electrical connections
should be performed by a qualifi ed electrician.
Installation must be in accordance with local codes
and national electrical codes.
WIRING
1. Local electrical wiring codes differ from area to area.
Source wiring, plug and protector must be rated for
at least the amperage and voltage indicated on motor
nameplate, and meet all electrical codes for this minimum.
2. Use a slow blow fuse or a circuit breaker.
3. This product is for use on a nominal 120 volt circuit and
has a grounding plug that looks like the plug illustrated in
Figure 6.
Grounding Pin
Figure 6 - Grounding Method
Make sure the product is connected to an outlet having
the same confi guration as the plug. This product must
be grounded. In the event of an electrical short circuit,
grounding reduces risk of electrical shock by providing an
escape wire for electric current. This product is equipped
with a cord having a grounding wire with an appropriate
grounding plug. Plug must be plugged into an outlet that
is properly installed and grounded in accordance with all
local codes and ordinances.
Overheating, short circuiting and fi re
damage will result from inadequate wiring.

Operation

BEFORE FIRST START-UP
BREAK-IN PROCEDURE
(Complete this procedure before using compressor for the first
time. Once completed, it is not necessary to repeat.)
1. Open drain valve located on bottom of tank.
2. Turn ON / OFF switch to OFF position.
Grounded Outlet
TEST
RESET
Minimum Gauge of Extension Cord
25 ft.
14
Use of an extension cord may cause excess heat to motor. This could
lead to tripped breaker (at electrical panel) or tripped thermal
overload (on compressor motor). If this occurs, eliminate extension
cord and plug compressor directly into electrical outlet. Avoid using
extension cords; use longer air hose(s) instead.
3. Plug in power cord.
4. Turn ON / OFF switch to ON position and run compressor
for 30 minutes.
5. Turn ON / OFF switch to OFF position.
6. Unplug power cord.
7. Close drain valve.
The compressor is now ready for use.

OPERATING PROCEDURE

1. Turn switch to OFF position and plug in power cord.
2. Turn regulator knob counterclockwise to close air flow.
3. Turn switch to AUTO position.
4. Compressor will build to maximum pressure and shut off.
5. With hose attached to outlet of compressor, attach tire
chuck or other tool to open end of hose.
6. Adjust regulator to proper pressure for tool or tire.
Operate tool per instructions.
As air is depleted from the tank by use of a tire chuck, tool,
etc., the compressor will restart automatically at its preset
"cut-in" pressure. When a tool is being used continuously, the
compressor will cycle on and off automatically.
7. Turn switch to OFF position, unplug power cord and drain
tank of air and moisture when finished using compressor.
5
HU350899
50 ft.
100 ft.
12
10
www.campbellhausfeld.com
Tabla de contenido
loading

Tabla de contenido