Checking Operation; Before You Call For Service - Frigidaire FFEH3051VS Instrucciones De Instalación

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

30" ELECTRIC RANGE INSTALLATION INSTRUCTIONS
Direct Electrical Connection to the Circuit
Breaker, Fuse Box or Junction Box
If the appliance is connected directly to the circuit
breaker, fuse box or junction box, use fl exible,
armored or nonmetallic sheathed copper cable
(with grounding wire). Supply a U.L. listed strain-
relief at each end of the cable. At the appliance
end, the cable goes through the Direct Connection
Hole (see Figure 9) on the Cord Mounting Plate.
Wire sizes (copper wire only) and connections
must conform to the rating of the appliance.
Where local codes permit connecting the
appliance-grounding conductor to the neutral
(white) wire (see Figure 10):
1. Be sure that no power is supplied on the cable
from residence.
2. Follow instructions on previous page for Four
Conductor Wire Connection to Range (Fig. 9).
3. In the circuit breaker, fuse box or junction box
(Fig. 10):
a) Connect the green (or bare copper) wire,
the white appliance cable wire, and the neutral
(white) wire together.
b) Connect the 2 black wires together.
c) Connect the 2 red wires together.
Cable from Residence
Neutral
(white) Wire
Red
Wires
Green
(or Bare
Copper) Wire
Cable from
Appliance
NOTE: Be sure to remove
the supplied grounding strap.
Figure 10
3-Wire (Grounded Neutral) Electrical System
(Example: Junction Box)
Black
Wires
Junction
Box
White Wire
U.L.-listed Conduit
Connector (or CSA
listed)
7
Where local codes DO NOT permit connecting
the appliance-grounding conductor to the neutral
(white) wire, or if connecting to 4-wire electrical
system (see Figure 11):
1. Be sure that no power is supplied on the cable
from residence.
2. Follow instructions on previous page for Four
Conductor Wire Connection to Range (Fig. 9).
3. In the circuit breaker, fuse box or junction box
(Fig. 11):
a) Connect the white appliance cable wire to the
neutral (white) wire.
b) Connect the 2 black wires together.
c) Connect the 2 red wires together.
d) Connect the green (or bare copper) grounding
wire to the grounding wire of the circuit
breaker, fuse box or junction box.
Cable from
Green (or Bare
Residence
Copper) Wire
Red
Wires
Green (or Bare
Copper) Wire
Junction
Box
Cable from
Appliance
NOTE: Be sure to remove the
supplied grounding strap.
Figure 11
4-Wire Electrical System (Example: Junction Box)

6. Checking Operation

Refer to the Use and Care Guide for operation.
Do not touch cooktop glass or
CAUTION
elements. They may be hot enough to burn you.

Before You Call for Service

Read the Before You Call for Service Checklist
and operating instructions in your Use and Care
Guide. It may save you time and expense. The
list includes common occurrences that are not the
result of defective workmanship or materials in this
appliance.
Refer to your Use and Care Guide for Sears service
phone numbers, or call 1-800-4-MY-HOME
White
Wire
Black
Wires
White Wire
U.L.-listed Conduit
Connector (or CSA
listed)
.
®

Hide quick links:

Tabla de contenido
loading

Tabla de contenido