PROBLEM
Excessive tank
pressure -
safety valve
pops off.
Air leaks at
fittings.
Air leaks at or
inside check
valve.
Air leaks at
pressure switch
release valve.
(if equipped)
Air leaks in air
tank or at air
tank welds.
Air leaks
between head
and valve plate.
D24225

TROUBLESHOOTING

Performing repairs may expose voltage sources, moving
parts or compressed air sources, moving parts or
CAUSE
Pressure switch does not
shut off motor when
compressor reaches "cut-
out" pressure.
Pressure switch "cut-out"
too high.
Tube fittings are not tight
enough.
Check valve seat damaged.
Defective pressure switch
release valve.
Defective air tank.
Leaking seal.
Move On/Auto/Off lever to
the "OFF" position, if the
outfit does not shut off
contact a Trained Service
Technician.
Contact a Trained Service
Technician.
Tighten fittings where air can
be heard escaping. Check
fittings with soapy water
solution. DO NOT
OVERTIGHTEN.
A defective check valve
results in a constant air leak
at the pressure release valve
when there is pressure in the
tank and the compressor is
shut off. Replace check
valve. Refer the "To Replace
or Clean Check Valve" in the
"Service and Adjustments"
section.
Contact a Trained Service
Technician.
Air tank must be replaced.
Do not repair the leak.
weld or otherwise modify
air tank or it will weaken.
The tank can rupture or
explode.
Contact a Trained Service
Technician.
22- ENG
CORRECTION