PARAMETER
VALUE
En.SA
no
Si
t.AP1
0.0"-5'00
t.AP2
0.0"-5'00
t.Ch1
0.0"-5'00
t.Ch2
0.0"-5'00
P.APP
0 - 100
r.AP
0.0" - 1'00
r.Ch
0.0" - 1'00
DESCRIPTION
ENERGY SAVING function
When the function is active and the LOW ENERGY module is installed,
the control unit deactivates the display, the photocells, and all the
devices powered by a terminal box under determined conditions.
NOTE: If the LOW ENERGY module is not installed, the control unit
deactivates only the display.
The control unit activates the ENERGY SAVING mode under the
following conditions:
• 30 seconds after completion of an operational cycle
• 30 seconds after an opening (if automatic closure is not enabled)
• 30 seconds after exiting the programming menu
The control unit exits from the ENERGY SAVING mode in these cases:
• If an operational cycle is activated
• If one of the keys on the control unit are pressed
Function deactivated
Function activated
Leaf 1 opening time
Adjustable time from 0 seconds to 5 minutes
Leaf 2 opening time
Adjustable time from 0 seconds to 5 minutes.
WARNING: if motor M2 is not connected, this time must be set to
zero
Leaf 1 closing time
Adjustable time from 0 seconds to 5 minutes.
NOTE: To avoid that the door does not close completely, we
recommend to setup a longer time than
Leaf 2 closing time
Adjustable time from 0 seconds to 2 minutes
NOTE: To avoid that the door does not close completely, we
recommend to setup a longer time than
Partial opening (leaf 1 only)
The percentage of the path the gate performs in the case of opening
using the Pedestrian Start command
Opening door delay
During the opening phase, leaf 1 must start moving before leaf 2, to
avoid that both doors may collide.
Leaf 2 opening will be delayed for the setup time.
NOTE: If you set the opening door delay to zero, the control board
does not execute the control of the correct leaves closing order
Closing door delay
During the closing phase, leaf 1 must start moving after leaf 2, to
avoid that both doors may collide.
Leaf 1 closing will be delayed for the setup time
t.AP1
opening time.
t.AP2
opening time
- 24 -
AntE SCor
MEMO
no
no
20.0" 22.5"
20.0" 0.0"
21.0" 23.5"
21.0"
0.0"
25
25
1.0"
0.0"
3.0"
0.0"