INSTALLATION
SECTIONAL DOOR: fix the transmission guide at the centre of the sectional door, directly above the spring post
using suitable screws and plugs. The guide should ideally be installed at approx. 40 mm. above the section door
transit area (fig. 7 and 8). Level the guide and lock by means of the guide supports and relative brackets (fig.9). Fix
the leaf connection bracket at the highest end of the door. Then connect the bracket and transmission arm (fig. 10).
Fig. 7
Fig. 9
SPRING UP-AND-OVER DOOR: fix the transmission guide at the centre of the up-and-over door, above the
frame using suitable screws and plugs.
The guide should ideally be installed at approx. 40 mm above the door transit area (as per sectional doors). Level
the guide and lock by means of the guide supports and relative brackets supplied (fig. 9). Fix the leaf connection
bracket at the highest end of the door. Then connect the bracket and transmission arm (fig. 10).
COUNTERWEIGHT UP-AND-OVER DOOR: the adaptor arm code no. BO should be fixed at the centre of the
up-and-over door on the highest cross-member and at the end opposite one of the horizontal cross-members.
A slight deviation is admissible for side fixture of the handle (fig. 11). Fix the transmission guide at approx. 20-50
mm from the maximum door opening position (fig. 12) using suitable screws and plugs. Level the guide and lock
by means of the guide supports and relative brackets (fig.9). Join the transmission arm with the end of the adaptor
arm by means of at least two screws and respective nuts (not supplied).