Please read and comply with these
instructions prior to the initial
operation of your appliance.
Retain these instruction manual for
future reference or for subsequent
possessors.
Note
All parts of the device and its acces-
sories are not allowed to be changed
or replaced , other than authorized
by the manufacturer or his agent.
Test on a known live source within the rated
ac voltage range of the product, both before
and after use to ensure unit is in good working
condition.
When using the Tester, if tip does not glow,
voltage could still be present. The Tester
indicates active voltage in the presence of
electrostatic fields of sufficient strength gener-
ated from the source (mains) voltage. If the
field strength is low, the Tester may not provide
indication of live voltages. Lack of an indica-
tion occurs if the Tester is unable to sense the
presence of voltage which may be influenced
by several factors including, but not limited to:
• Shielded wire/cables
• Thickness and type of insulation
• Distance from the voltage source
• Fully-isolated users that prevent an effective
ground
• Receptacles in recessed sockets/differences
in socket design
• Condition of the Tester and Batteries

For your safety

In case you do not adhere to this instruction
manual and the safety instructions, this may result
in damage on the device and cause dangerous
situations for the operator and other people.
In case of transport damage inform vendor
immediately.

Safety instructions

For use by competent persons.
Anyone using this instrument should be
knowledgeable and trained about the risks
involved with measuring voltage, especially
in an industrial setting, and the importance of
taking safety precautions and of testing the
instrument before and after using it to ensure
that it is in good working condition.
Only use genuine Würth accessories
and spare parts.
WARNING - Prior to the first
start-up, it is definitely necessary to
read the Safety instructions!
Caution
Use caution with voltages above
30 V AC as a shock hazard may
exist.
Caution
The single-pole phase testing is not
appropriate to determine whether a
line is live or not. For this purpose,
the double-pole voltage test is always
required.
7