Installation
(Cont.)
a. No other electrical appliances or lights
are connected to the same branch
circuit.
b. Voltage supply is normal.
c. Extension cords are of the minimum
gauge specified in this instruction
manual.
d. Circuit is equipped with a 15 amp
circuit breaker or a 15 amp slow blow
fuse type T.
3. If above conditions cannot be met or
if nuisance tripping of current
protection device occurs, it may be
necessary to operate compressor from
a 115 volt, 20 amp circuit.
GROUNDING INSTRUCTIONS
1. This product should be grounded. In
the event of an electrical short
circuit, grounding reduces risk of
electrical shock by providing an
escape wire for electric current. This
product is equipped with a cord
having a grounding wire with an
appropriate grounding plug. Plug
must be plugged into an outlet that
is properly installed and grounded
in accordance with all local codes
and ordinances.
Grounding
TEST
RESET
Pin
Figure 3 - Grounding Method
Improper use of
grounding plug can
result in a possible risk of electrical shock!
NOTE: Do not use grounding adapter.
2. If repair or replacement of cord or
plug is necessary, do not connect
grounding wire to either flat blade
terminal. The wire with insulation
having an outlet surface that is green
with or without yellow stripes is the
grounding wire.
Length of Cord (ft)
Gauge of Cord
Wire
Power cord
Motor cord
Power cord
Motor cord
(✽) When the unit is not in operation
3. Check with a qualified electrician or
serviceman if grounding instructions
are not completely understood, or if
in doubt as to whether product is
properly grounded. Do not modify
plug provided; if it will not fit outlet,
have proper outlet installed by a
qualified electrician.
yellow) wire to a live terminal.
ExTENSION CORDS
1. Use only a 3-wire extension cord that
has a 3-blade grounding plug, and a
3-slot receptacle that will accept plug
on product.
2. Make sure extension cord is in good
condition, and heavy enough to carry
current product will draw. An
undersized cord will cause a drop in
line voltage resulting in loss of power
and overheating.
3. To avoid loss of power and
overheating, it is better to use
Grounded
additional air hose instead of
Outlet
extension cords to reach work area.
4. Table below shows correct size to use
depending on cord length and
nameplate ampere rating. If in doubt,
use next heavier gauge.
NOTE: The smaller the gauge number,
the heavier the cord.
5. This product is for use on a nominal
120 volt circuit and has a grounding
plug that looks like plug illustrated in
Figure 2. Make sure that product is
connected to an outlet having same
configuration as plug.
Extension cords for 120V/15 Amp Unit
25
50
100
14
10
10
WL5000 Series Contractor Models
✽ Wire and Terminal Guide
Color
White
White
Black
Black
Operation
FOR TROUbLE-FREE OPERATION
1. Read instructions: Carefully read
2. Break in: Allow new compressor to
Never connect
green (or green and
3. Drain tank daily: Open drain cock and
Do not use adapter
with this product!
150
200
250
8
6
6
3
Terminal
Hot
Line
No
Load
No
Line
Yes
Load
Yes
through this owner's manual BEFORE
OPERATING the new air compressor.
It contains information about
operation and maintenance of unit.
run for at least 30 minutes without
compressing air, to properly seat
working parts. See Break-In
instructions on page 4.
drain moisture from tank. Be sure to
MOISTURE IN COMPRESSED AIR
Moisture in compressed air will
form into droplets as it comes
from an air compressor pump.
When humidity is high or when a
compressor is in continuous use
for an extended period of time,
this moisture will collect in the
tank. When using a paint spray or
sandblast gun, this water will be
carried from the tank through the
hose, and out of the gun as
droplets mixed with the spray
material.
IMPORTANT: This condensation
will cause water spots in a paint
job, especially when spraying
other than water based paints. If
sandblasting, it will cause the
sand to cake and clog the gun,
rendering it ineffective.
A filter in the air line, located as
near to the gun as possible, will
help eliminate this moisture.
300
400
4
4
500
2