Operating Instructions - Schumacher Electric SPEEDCHARGE SC-8020A El Manual Del Propietario

Ocultar thumbs Ver también para SPEEDCHARGE SC-8020A:
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

remaining cool down time in seconds. It starts at 180 and counts down
to 0. The ENGINE START LED blinks once every second. During the
cool down period, no current is delivered to the battery. After 3 minutes,
the ENGINE START LED will stop blinking and will light continuously,
indicating that another crank cycle can be started. The digital display
will change from displaying the countdown back to displaying the
battery voltage. The CHARGING LED will then be lit.
ENgiNE STARTiNg NOTES:
If the battery is disconnected during the cool down period, the charger
will reset.
11.

OpERATiNg iNSTRUCTiONS

OVERViEW: Using this battery charger is very simple. First, connect
the battery and AC power. Then select the appropriate BATTERy TyPE
and BATTERY SIZE for your battery. The charger will then do everything
automatically. This section explains a few details.
11.1
ChARgiNg:
the CONNECTED LED will not light. Charging will not begin unless the
CONNECTED LED is on. When charging begins, the CHARGING LED will
be lit.
11.2
AUTOMATiC ShUT OFF:
LARGE BATTERY SIZE is selected, the charger is set to perform an auto-
matic charge. When an automatic charge is performed, the charger stops
charging automatically after the battery is charged.
11.3
ABORTED ChARgE:
will be aborted. When charging is aborted, the charger's output is shut off
and the digital display blinks on and off. In that state, the charger ignores
all buttons. To reset from after an aborted charge, either disconnect the
battery or unplug the charger.
11.4
DESULFATiON MODE:
period, it could become sulfated and not accept a normal charge. If the
charger detects a sulfated battery, the charger will switch to a special
mode of operation designed for such batteries. Activation of the special
desulfation mode is indicated by blinking the CHARGING LED. If suc-
cessful, normal charging will resume after the battery is desulfated. The
CHARGING LED will then stop blinking and light continuously. Desulfation
could take up to 10 hours. If desulfation fails, charging will be aborted and
the digital display will blink.
If the charger does not detect a properly connected battery,
When the SMALL BATTERy or MEDIUM TO
If charging can't be completed normally, charging
If a battery is left discharged for an extended
7

Capítulos

Tabla de contenido
loading

Tabla de contenido