EXHAUST AND SUPPLY NETWORK
The ducting installation is composed of insulated PVC ducting
The duct layout should be as simple as possible :
- avoid long ducting runs and severe angles or bends
- install the duct with large sweeping bends
- the flexible duct should not be deformed or flattened
The exhaust network consists of Ø125 mm flexible ducting for the kitchen and Ø80 mm for other rooms such as
bathrooms, toilets etc.
The spigot of the exhaust fan is connected to a roof outlet with duct of Ø150 mm.
The supply network consists of derivations Y branch Ø150/ Ø125/ Ø60. In the case of large dwelling, it is possible
to use a derivation Ø150/Ø150/Ø150 in order to realise parallel supply networks
The fresh air intake is done with duct in Ø150 mm.
IMPORTANTADVICE : cover the overall duct system with a layer of glass wool (70 mm) so as to avoid
condensation.
EXTRACT
SUPPLY
D3
Ø60
Ø 125
L4
I3
D3
D3
Possibility n°1
NUMBERS OF EXTRACT & SUPPLY VALVES
Kitchen valve
Sanitary valve 30 m³/h
Sanitary valve 15 m³/h
Valves CD
REALISATION OF EXTRACT & SUPPLY NETWORKS
CD
D4
D2
Ø 125
Ø 150
EP OR ESA
I3
L3
D2
D1
D2
EP OR ESA
T2/3
1
1
1
4 to 6
Ø
L1
15
0
Ø
D1
150
Possibility n°2
L1 + L2---------------MAXI 6m
Ø
L3----------------------MAXI 12 m (with l3 mini 1.5 m)
L1
15
L4----------------------MAXI 6m
0
-Possiblity to inctrease L1 & L2 if L3 is < to 12m
-If L3 is < to 12 m L1+L2+L3 MAXI 18m
T4/T5 T6/T7
GD
1
1
1
2
2
4
-
2
-
5 to 7 7 to 9
9 to 12
L1------------------MAXI 6m
L2------------------MAXI 6m
EXHAUST
L3------------------MAXI 6M
L3
Ø 80
Ø 125
L2