Wolf SW 24 Manual Del Usuario página 8

Cuadro de control para puertas batientes
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

WOLF SW 24: CONTROL BOARD FOR SWING GATES
SOT STOP (GREEN)
Soft stop motor regulation. Only with Option 7 ON. Rotate to the LEFT to
decrease it and rotate to the RIGHT to increase it. Available for opening and
closing.
AUTOMATIC CLOSING TIME (BLACK)
Regulates the stand-by time before the automatic closure. Turn to the LEFT to decrease
it and to the RIGHT to increase it.
Minimum 3 seconds.
Maximum 120 seconds.
1 AUTOMATIC CLOSURE
ON: Activated. Door closes automatically.
OFF: Deactivated. Door does not close automatically.
2 DEACTIVATION STOP OPENING
ON: Door can not stop while opening.
OFF: Doors stop while opening by pressing the TRANSMITTER, GATE1 or ALTER (15- 16) on
board.
3 RADIO PROGRAMMING
ON: Not allowed.
OFF: Allowed.
4 INVERSION SHUT
Before opening, the electro lock and closure relay are activated. At the end of the
ON:
closing maneuver tightening time 2 sec for safety.
Normal opening with electro lock.
OFF:
5
CSEG (11-12) input stops and inverts 2 seconds the opening maneuver. On
ON:
closing, stops and inverts the maneuver.
CSEG1 (11-12) input stops the opening maneuver. When CSEG1 is deactivated,
OFF:
the door opens again.
6 FLASHING LIGHT
Flashing.
ON:
OPTIONS
8
Tabla de contenido
loading

Tabla de contenido