Maintenance and cleaning
WARNING! RISK OF INJURY!
Disconnect the tool from the
compressedair supply.
CAUTION!
►
Before maintenance, clean off any hazardous
substances that may (due to working pro-
cesses) have accumulated on the tool . Avoid
all skin contact with these substances . If the
skin comes into contact with hazardous dusts,
this can lead to severe dermatitis . If dust is
produced or swirled up during maintenance,
it can be inhaled .
NOTE
►
To ensure correct functioning and long-term
durability of the tool, pay attention to the
following points:
■
Sufficient and continuous oil lubrication is highly
important for optimum functioning .
■
Check the speed and vibration levels after each
use .
■
Check the idle speed regularly and after any
maintenance is performed:
Use a rev counter and perform the measure-
ment without any clamped tools . At a residual
pressure of 6 .8 bar, the idle speed may not be
exceeded under any circumstances .
■
If the tool is exhibiting excessive vibration levels,
the cause of the vibrations must be identified
and repaired .
■
Use only the genuine replacement parts
recommended by the manufacturer, otherwise
you could put users at risk . In doubt, contact the
Service Centre .
■
Clean the tool with a soft, dry cloth only .
■
Never use sharp or abrasive cleaning agents
under any circumstances .
PDBS 1800 A1
Troubleshooting
Fault
Possible
cause
Speed too
Motor parts
slow, air
jamming due
escapes from
to dirt .
the outlet .
Pressure
supply too
low .
Tool does
Motor is
not move;
jammed due
compressed
to material
air escapes
build-up .
completely
through the
outlet .
Remedy
Check the
pressure
supply filter
for contamina-
tion .
Check the
pressure sup-
ply filter for
contamination .
Lubricate the
tool as de-
scribed in the
instructions .
If necessary,
repeat the
steps outlined
above .
Lubricate the
tool as de-
scribed in the
instructions .
GB │ MT
│
45
■