4. LIGHTING AND REGULATING COMBUSTION
The Insert Fireplace must be closed at all times
during combustion to prevent smoke from
leaking out. Only open to reload.
Follow
the
instructions
combustion:
- BY MOVING the control handle from back to front,
you cut off the air for combustión CLOSE(C) (see
the figure).
- TO FACILITATE turning the equipment on, we
recommend turning the control handle completely
towards the inside OPEN(O).
It is essential to provide an abundant load of fuel
when lighting. The following loads will depend on
the heat requirement desired.
It is advisable to leave the door partially open to
avoid condensation and keep the glass clean for
some minutes after lighting the fire.
Once the fireplace has got going at its normal level
and the chimney has heated up, regulate
combustion by means of the regulation lever. When
the inflow of air is fully closed, combustion will be
slow; when the inflow of air is open, combustion will
be more intense.
In order to make the most of your device, place
the combustion regulation lever in the central
position.
When the device is to be used in the same room as
other
heating
devices
combustion
purposes,
additional inflow of air from outside to facilitate
combustion in all the said devices.
The use of one or more heating devices in the
same room reduces the level of available oxygen,
affecting the combustion of the fireplace and
reducing the draw of the chimney.
below
to
regulate
that
require
air
for
we
recommend
an
ATTENTION! When working, the metal parts of
the fireplace may reach high temperatures.
Protect your hands with a fireproof glove when
touching the said parts.
If you should detect any overheating of the
fireplace caused by:
Fan breakdown.
Faulty thermostat.
You should shut down the device in order to avoid
damaging
cast
iron
recommendations:
 Do not add any more fuel
 Open the door slightly to let more air in; this will
cause the flames to grow and consume the fuel
more quickly but will also cool the chimney and
reduce draw, cooling the device
Your Insert Fireplace has not been designed to
operate
with
an
system.
For a correct operation of the device, make sure
that the inner baffle is sticking with the rear and
that it is centered with respect to the sides.
parts.
Follow
intermittent
combustion
these