Logic
Definition
Configuration of
command input IC 1.
IC 1
Configuration of
command input IC 2.
IC 2
Configuration of
AUX 0 output.
AUX 0
20-21
Configuration of
AUX 3 output.
AUX 3
26-37
Fixed code
FIXED CODE
Protection
Setting the
protection level
level
Serial mode
(Identifies how board
SERIAL ODE
is configured in a BFT
network connection).
Address
ADDRESS
32
GIOTTO BT A ULTRA 36
Cross out
Default
setting
used
0
1
2
2
61
3
4
3
5
62
0
1
2
3
6
4
5
6
7
8
9
10
1
11
12
13
14
0
0
1
0
1
0
2
3
4
0
1
0
2
3
[ ___ ]
0
ENGLISH
Input configured as Start E.
Input configured as Start I.
Input configured as Open.
Input configured as Close.
Input configured as Ped.
Input configured as Timer.
Output configured as 2nd Radio Channel.
Output configured as SCA (gate open light).
Output configured as Courtesy Light command.
Output configured as Zone Light command.
Output configured as Stair Light
Output configured as Alarm
Output configured as Flashing light
Output configured as Latch
Output configured as Magnetic lock
Output configured as Maintenance
Output configured as Flashing Light and Maintenance.
Not available
output configured as barrier status
Lights on bar - open green, moving red flashing, closed red steady.
Lights on bar - open green, moving red flashing, closed red flashing.
Receiver is configured for operation in rolling-code mode.
Fixed-Code Clones are not accepted.
Receiver is configured for operation in fixed-code mode.
Fixed-Code Clones are accepted.
A - The password is not required to access the programming menus
B - Enables wireless memorizing of transmitters.
Operations in this mode are carried out near the control panel and do not require access:
- Press in sequence the hidden key and normal key (T1-T2-T3-T4) of a transmitter that has already been
memorized in standard mode via the radio menu.
- Press within 10 sec. the hidden key and normal key (T1-T2-T3-T4) of a transmitter to be memorized.
The receiver exits programming mode after 10 sec.: you can use this time to enter other new transmitters
by repeating the previous step.
C - Enables wireless automatic addition of clones.
Enables clones generated with the universal programmer and programmed Replays to be added to
the receiver's memory.
D - Enables wireless automatic addition of replays.
Enables programmed Replays to be added to the receiver's memory.
E - The board's parameters can be edited via the U-link network
A - You are prompted to enter the password to access the programming menus
The default password is 1234.
No change in behaviour of functions B - C - D - E from 0 logic setting
A - You are prompted to enter the password to access the programming menus
The default password is 1234.
B - Wireless memorizing of transmitters is disabled.
C - Wireless automatic addition of clones is disabled. No change in behaviour of functions D - E from 0 logic setting
A - You are prompted to enter the password to access the programming menus
The default password is 1234.
B - Wireless memorizing of transmitters is disabled.
D - Wireless automatic addition of Replays is disabled.
No change in behaviour of functions C - E from 0 logic setting
A - You are prompted to enter the password to access the programming menus
The default password is 1234.
B - Wireless memorizing of transmitters is disabled.
C - Wireless automatic addition of clones is disabled.
D - Wireless automatic addition of Replays is disabled.
E - The option of editing the board's parameters via the U-link network is disabled.
Transmitters are memorized only using the relevant Radio menu.
IMPORTANT: This high level of security stops unwanted clones from gaining access and also stops radio
interference, if any.
Standard SLAVE: board receives and communicates commands/diagnostics/etc.
Standard MASTER: board sends activation commands (START, OPEN, CLOSE, PED, STOP) to other boards.
SLAVE opposite leaves in local network : the control unit is the slave in an opposite leaves network
with no smart module (fig.L)
MASTER opposite leaves in local network: the control unit is the master in an opposite leaves network
with no smart module (fig.L)
Identifies board address from 0 to 119 in a local BFT net wor k connec tion.
(see U-LINK OPTIONAL MODULES section)
Optional extras