x2
***
0---
10--
ALT
follow the user guide
add. start
hidden butt
Add. 2ch
hidden butt
erase 64
language
Control unit
software version
stat
OK
vers
bft . . .
+/-
No total
- +
manoeuvres(in hundreds)
OK
0000
n. cycles
+/-
- +
No radio control
devices memorised
00
n. remotes
OK
+/-
- +
List of last 30 errors
01.33
err
OK
02.01
........
30.15
0---
password
ACCESS MENUS Fig. 2
150-
1520
See PARAMETERS MENU
See LOGIC MENU
release
desired button
release
desired button
See RADIO MENU
Diagnostics
code
START E external start input activated
STRE
START I internal start input activated
STRI
OPEN input activated
OPEN
CLOSE input activated
CLS
TIMER input activated
TI E
STOP input activated
STOP
Activation of PHOT photocell input or, if configured as verified
PHOT
photocell, Activation of the associated FAULT input
Activation of PHOT OP opening photocell input or, if configured
as active verified photocell only when opening, Activation of
PHOP
the associated FAULT input
Activation of PHOT CL closing photocell input or, if configured
as active verified photocell only when closing, Activation of
PHCL
the associated FAULT input
Activation of BAR safety edge input or, if configured as verified
BAR
safety edge, Activation of the associated FAULT input
Activation of BAR safety edge input on slave motor (opposing
door connection) or, if configured as verified safety edge,
BAR 2
Activation of the associated FAULT input
SWC motor closing limit switch input activated
SWC
SWO motor opening limit switch input activated
SWO
Enabling input reference opening
refo
Enabling input reference closing
refc
Photocell test failed
ER01
Safety edge test failed
ER02
Opening photocell test failed
ER03
Closing photocell test failed
ER04
Safety edge test on slave motor failed (opposite leaves
ER05
connection)
8k2 safety edge test failed
er06
Board hardware test error
ER1x*
Encoder error
ER2x**
Reverse due to obstacle - Amperostop
ER3x*
Thermal cutout
ER4x*
Communication error with remote devices
ER5x*
ER70, ER71
Internal system supervision control error.
ER74, ER75
Consistency error of the control unit's parameters (Logics
ER72
and Parameters)
D-track parameter error
+/-
ER73
limit switch error
ErFx*
Error in setting the SAFE inputs
ERf3
* X = 0,1,...,9,A,B,C,D,E,F
10--
150-
ok
Request with Protection Level logic set to 1, 2, 3, 4
DESCRIPTION
1520
*** Password entry.
Scroll up
Scroll down
Con rm/Switch on display
Exit Menù
NOTES
Check photocell connection and/or logic settings
Check safety edge connection and/or logic settings
Check photocell connection and/or parameter/logic setting
Check photocell connection and/or parameter/logic setting
Check safety edge connection and/or parameter/
logic settings
Check safety edge connection and/or parameter/
logic settings
-Check connections to motor
-Hardware problems with board (contact technical
assistance)
Check the cable, the encoder card and the motor direc-
tion (if necessary) and reset the card
Check for obstacles in path
Allow automated device to cool
Check connection with serial-connected accessory
devices and/or expansion boards
Try switching the board off and back on again. If the
problem persists, contact the technical assistance
department.
Pressing OK the detected settings are confirmed. The
board will keep on working with the detected settings.
The board settings must be checked (Parameters
and Logics)
Pressing OK, the board will keep on working with D-
track as a default.
An autoset is required
Check limit switch connections
Check if the SAFE inputs are correctly set; during the
operation of opposed barriers, SAFE2 must be set up
as safety edge. Fig. L
prg
GIOTTO BT A ULTRA 36 -
27