Troubleshooting Tips
COMPLAINT
Unit does not operate.
Unit Trips Circuit Breaker or
Blows Fuses.
LCDI Power Cord Trips
(Reset Button Pops Out).
Unit Does Not Cool/ Heat Room
Sufficiently, or Cycles On And Off
Too Frequently.
CAUSE
•
The unit is turned to the off position, or the
thermostat is satisfied.
•
The LCDI power cord is unplugged.
•
The LCDI power cord has tripped (Reset
button has popped out).
•
The circuit breaker has tripped or the
supply circuit fuse has blown.
•
There has been a local power failure.
•
Other appliances are being used on the
same circuit.
•
An extension cord is being used.
•
The circuit breaker or time-delay fuse is
not of the proper rating.
•
The LCDI power cord can trip (Reset
button pops out) due to disturbances on
your power supply line.
•
Electrical overload, overheating, or cord
pinching can trip (Reset button pops out)
the LCDI power cord.
NOTE:
A damaged power supply cord must be replaced with a new power supply cord obtained from the
product manufacturer and must not be repaired.
•
The return/ discharge air grille is blocked.
•
Windows or doors to the outside are open.
•
The temperature is not set at a cool
enough/ warm enough setting.
•
The filter is dirty or obstructed.
•
The indoor coil or outdoor coil is dirty or
obstructed.
•
There is excessive heat or moisture
(cooking, showers, etc.) in the room.
•
The temperature of the room you are
trying to cool is extremely hot.
SOLUTION
•
Turn the unit to the on position and raise or lower
temperature setting (as appropriate) to call for
operation.
•
Plug into a properly grounded 3 prong receptacle.
See "Electrical Rating Tables" on Page 5 for the
proper receptacle type for your unit.
•
Press and release RESET (Listen for click. Reset
button latches and remains in.) to resume operation.
•
Reset the circuit breaker, or replace the fuse as
applicable. If the problem continues, contact a
licensed electrician.
•
The unit will resume normal operation once power
has been restored.
•
The unit requires a dedicated outlet circuit, not shared
with other appliances.
•
Do NOT use an extension cord with this or any other
air conditioner.
•
Replace with a circuit breaker or time-delay fuse of
the proper rating. See "Electrical Rating Tables" on
Page 5 for the proper circuit breaker/ fuse rating for
your unit. If the problem continues, contact a licensed
electrician.
•
Press and release RESET (Listen for click. Reset
button latches and remains in.) to resume normal
operation.
•
Once the problem has been determined and
corrected, press and release RESET (Listen for
click. Reset button latches and remains in.) to
resume normal operation.
•
Ensure that the return and/ or discharge air paths are
not blocked by curtains, blinds, furniture, etc.
•
Ensure that all windows and doors are closed.
•
Adjust the Temperature control to a cooler or warmer
setting as necessary.
•
Clean the filter, (See Routine Maintenance), or
remove obstruction.
•
Clean the coils, (See Routine Maintenance), or
remove obstruction.
•
Be sure to use exhaust vent fans while cooking or
bathing and, if possible, try not to use heat producing
appliances during the hottest part of the day.
•
Allow additional time for the air conditioner to cool off
a very hot room.