Installation Instructions
Mounting the Hood
1. Using 2 or more people, lift the hood into final position. Feed enough
electrical wire through the ½" UL listed or CSA approved strain relief
to make connections in the terminal box. Tighten the strain relief
screws.
2. Position the range hood so that the large end of the keyhole slots are
over the mounting screws. Then push the hood toward the wall so
that the screws are in the neck of the slots. Install the .5 cm x 4.5 cm
mounting screws in drywall anchors.
A
A. Mounting screws (4)
B. Security screws
3. Tighten the mounting screws, making sure the screws are in the
narrow neck of slots.
4. Tighten the security screws to the wall.
5. For direct wire installations, run the home power supply cable
according to the National Electric Code or CSA standards and local
codes and ordinances. There must be enough wiring from the fused
disconnect (or circuit breaker) box to make the connection in the
range hood electrical terminal box.
NOTE
Do not reconnect power until the installation is complete.
OPTIONAL: If you prefer, bend the rear tabs against the rear of the range
hood and attach to the wall using #8-18 x 5/8" (4.2 x 16 mm) truss-head
screws.
Connect Vent System
1. Connect the vent work to the range hood.
2. Seal joints with vent clamps or duct tape to make secure and airtight.
3. Check that the backdraft dampers work properly.
Electrical Connection
ELECTRICAL SHOCK HAZARD.
DISCONNECT POWER BEFORE SERVICING. REPLACE ALL PARTS
AND PANELS BEFORE OPERATING. FAILURE TO DO SO CAN
RESULT IN DEATH OR ELECTRICAL SHOCK.
B
1. Remove the knockout and the Junction box cover, and then install the
2. Run 3 wires - black, white, and green - according to the National
3. Connect the black wire from the service panel to the black or the
4. Close and secure the junction box cover.
Completing the installation
1. Replace the filters and check the operation of the hood.
2. Replace the filter.
If the range hood does not operate:
•
•
•
•
WARNING
A
B
C
D
conduit connector (cULus listed) in the junction box.
Electrical Code and local codes and ordinances, in 1⁄2" conduit from
the service panel to the junction box.
WARNING
ELECTRICALLY GROUND THE BLOWER. CONNECT THE GROUND
WIRE TO THE GREEN AND YELLOW GROUND WIRES IN THE
TERMINAL BOX. FAILURE TO DO SO CAN RESULT IN DEATH OR
ELECTRICAL SHOCK.
red in the junction box. Connect the white to white and green to
green-yellow.
• For vented installations: Install a metal filter.
• For non-vented (recirculating) installations: Install a charcoal
filter.
Confirm that the circuit breaker is not tripped or the house fuse
blown.
Disconnect the power supply, and then check if the wiring is correct.
To get the most efficient use from your new range hood, read the
"Range Hood Use" section.
Keep these Installation Instructions and Use and Care Guide close to
range hood for easy reference.
E
A. White wires
B. Black wires
C. UL listed wire connector
D. Green (or bare) and
yellow-green ground wire
E. Homepower supply cable
F. UL listed or CSA ap-
⁄
"
1
F
proved
strain relief.
2
English
11