Geared Motor References; Preliminary Checks; Geared Motor Installation - DITEC LUXO Serie Manual Para La Instalacion Y La Manutencion

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 26
1.
TECHNICAL DATA
GB
Power supply
Absorption
Thrust
Max run
Opening time
Service class
Intermittence
Temperature
Degree of protection
Control panel
Applications
m = leaf width
kg = leaf weight
Recommended
dimensions
Limit dimensions
2.
REFERENCE TO ILLUSTRATIONS
The given operating and performance features can only be guar-
anteed with the use of DITEC accessories and safety devices.
2.1 Standard installation references (fig. 1)
[1]
Radio
[2]
Flashing light
[3]
Key selector
[4]
Connect power supply to an type-approved omnipole
switch with a contact opening gap of no less that 3 mm
(not supplied by us)
[5]
Control panel
[6]
Geared motor
[7]
Photocells

2.2 Geared motor references

[8]
Rear bracket
[9]
Front bracket
[10] Cover
[11] Release access door
[12] Release
[13] Drive screw cover
[14] Drive screw
3.
INSTALLATION
Unless otherwise specified, all measurements are expressed
in millimetres (mm).

3.1 Preliminary checks

Check that the structure is sufficiently rugged and that the hinge
pivots are properly lubricated. Provide an opening and closing
stop.
Attention: LUXO3B-3R can only be installed if distance [C] is
either less than 70 mm or equal (fig. 3).
LUXO - IP1684
LUXO3R
LUXO3B
230 V~ / 50 Hz
230 V~ / 50 Hz
1.1 A
1.1 A
3000 N
3000 N
350 mm
350 mm
22 s / 90°
22 s / 90°
4 - INTENSIVE
4 - INTENSIVE
S2 = 20 min
S2 = 20 min
S3 = 50%
S3 = 50%
-20° C / +55° C
-20° C / +55° C
IP24D
IP24D
LOGICM
E2 - LOGICM
500 kg
400 kg
300 kg
200 kg
100 kg
1
2
3
4
[LUXO3R-3B]
LUXO3BH
24 V=
4 A
2000 N
350 mm
22 s / 90°
4 - INTENSIVE
S2 = 20 min
S3 = 50%
-20° C / +55° C
IP24D
D2HL - VIVAH
500 kg
400 kg
300 kg
200 kg
100 kg
5
m
1
2
3
[LUXO3BH]

3.2 Geared motor installation

-
Position rear bracket [8] on to the pillar to check installation
measurements (fig. 3) and secure it.
Note: the installation measurements given in the table in fig.
3 permit to select the values for [A] and [B] according to the
desired opening angle and with reference to existing room
and spaces. For proper operation, set [A] and [B] at values
between the minimum and maximum ones specified in the
table (compliance with the measurement given in the table
is recommended).
In order to ensure smooth gate movement, check that measure-
ments [A] and [B] are the same.
Increasing [A] decreases the coming up speed during opening.
Increasing [B] decreases the coming up speed during closing and
improves burglar-proofing.
Reducing [B] increases the extent of gate opening.
Measurements [A] and [B] must in any case be compatible with
the useful travel of the piston so that; if [A] is increased, [B] must
be decreased and vice versa.
-
Open the release access door [11] unscrew the screw [F]
and remove the cover [10]. Unscrew the screw [G] and
remove the drive screw covers [13]. Release the piston if
irreversible (see operating instructions).
10
J
12
12
LUXO5B
230 V~ / 50 Hz
1.1 A
3000 N
500 mm
32 s / 90°
20÷30 s / 90°
4 - INTENSIVE
4 - INTENSIVE
S2 = 20 min
S3 = 50%
-20° C / +55° C
-20° C / +55° C
IP24D
E2 - LOGICM
500 kg
400 kg
300 kg
200 kg
100 kg
4
5
m
1
2
[LUXO5B-5BH]
11
F
G
13
14
LUXO5BH
24 V=
12 A
3000 N
500 mm
S2 = 20 min
S3 = 50%
IP24D
VIVAH
3
4
5
m
Tabla de contenido
loading

Este manual también es adecuado para:

Luxo3rLuxo3bLuxo3bhLuxo5bLuxo5bh

Tabla de contenido