COMPONENTS
1
Sensor
2
Goose Neck
3
Buzzer
4
Battery Indicator (LED)
5
Concentration Indicator
6
Mute
7
Higher Sensitivity
8
Reset
9
Lower Sensitivity
10
ON / OFF
11
Battery Check
12
Battery Compartment
BATTERY
Note: please properly fix the battery according to the picture above.
BATTERY INDICATION
The leftmost LED is the indicator for the two-colour voltage.
Green
= Battery voltage is normal, sufficient for proper operation.
Orange
= Battery voltage is approaching the lower threshold for operation,
replace as soon as possible.
AUTOMATIC CIRCUIT/RESET FEATURE
This item features an Automatic circuit and a Reset function key that set the unit to ignore ambient
concentrations of refrigerant.
•
Automatic circuit: Upon initial power on, the unit automatically set itself to ignore the level of
refrigerant present at the tip. Only a level, or concentration, greater than this will cause an
alarm.
•
Reset Feature: Pressing the RESET key during operation performs a similar function. When
the RESET key is pressed, it programs the circuit to ignore the level of refrigerant present at
the tip.
The unit can be moved to fresh air and reset for maximum sensitivity. Resetting the unit with no
refrigerant present (fresh air) causes any level above zero to be detected.
Whenever the unit is reset, the LED (except the leftmost power indicator) will all turn off.