Troubleshooting

If your Drinks Dispenser develops a fault, please check the following points before making a call to the
Helpline.
Fault
The appliance is not
working
The dispenser is not
cooling
Tap leaks
Product leaks from the
back of the bowl
Loud noises
Tap does not distribute Ice blocked inside the bowl

Technical Specifications

Model
Voltage
DB331
220-240V~
50Hz
DB332
220-240V~
50Hz
DB843
220-240V~
50Hz
Dimensions
Model
H x W x D mm
DB331
810 x 270 x 515
DB332
810 x 470 x 515
DB843
810 x 670 x 515
DB331_DB332_DB843_ML_A5_v2_20210701.indb 11
DB331_DB332_DB843_ML_A5_v2_20210701.indb 11
Probable Cause
The appliance is not switched on
Plug or lead is damaged
Fuse in the plug has blown
Power supply
Coolant leak
Fan motor failed
Airflow obstructed to the
condenser
Tap piston not lubricated well
Tap piston is defective
Bowl not fitted correctly
Bowl seal not lubricated well
Bowl seal is defective
Front seal is not applied correctly
Seal not lubricated well
Power
Current
(W)
(A)
400W
2.1A
740W
3.5A
1150W
5.8
Weight
Noise level
(kg)
31.9
50.7
66.2
Solution
Check the appliance is plugged in correctly
and switched on
Call POLAR agent or qualified Technician
Replace the fuse
Check power supply
Call POLAR agent or qualified technician
Call POLAR agent or qualified technician
Increase the gap between appliance and
obstacles/heat source
Lubricate the tap piston
Replace the Tap piston
Check the positioning of the bowl
Lubricate the bowl seal
Replace the Bowl seal
Put the seal correctly
Lubricate the seal
Turn off the unit to let ice melt
Capacity
Bowls
(litres)
1
12
2
24
3
36
<70 dB
UK
Refrigerant
R290 85g
R290 135g
R290 148g
11