PROBLEM
The compressor
cooler is running
too long and is not
cooling properly.
An error code is
displayed on the
screen, the machine
is not cooling down.
EXPLANATION OF THE CODES DISPLAYED ON THE SCREEN
PROBLEM
Sensor circuit is broken or
E0
shorted.
E1
Voltage input is low.
E2
Ventilating fan problem.
Compressor started
E3
self-protection.
Compressor protects itself
E4
against unusual running speed.
Control panel's overheating
E5
warning
TECHNICAL DATA
Connection voltage
Rated current
Cooling temperature
Power consumption
Length of DC connection cable
Overall dimensions
Materials
Refrigerant
Insulation
Refrigeration system
POSSIBLE CAUSE
Good compressor cooler
performance, especially in
hot ambient temperatures,
is dependent on good air
flow around the compressor
cooler cooling slots.
Check "Explanation of the
codes displayed on the
screen".
POSSIBLE CAUSE
SUGGESTED REMEDY
Check that all ventilation slots
are unobstructed and there
is enough clearance for good
airflow around the compressor
cooler.
This defect can only be repaired
by an authorized service centre.
SUGGESTED REMEDY
Replace or connect the sensor.
Check the battery voltage or adjust the
battery monitor level ("H1", "H2", "H3").
Check if the ventilation fan is blocked or
shorted.
Disconnect the device from the power
supply for 30 minutes, and then restart
the device.
Change the operating mode via the
control panel on the device.
Move the device to a place with
a well-ventilated installation
environment.
12/24 V
(negative earth)
3,8 A/12 V (6.4 A Max)
1,9 A/24 V (3.2 A Max)
+20 °C to -22 °C (68 °F to -7.6 °F)
46 W (52.4W Max)
(Approx.) 3.5 meters
57.8 x 35 x 42 cm
PP, PU
R600
Polyurethane
Compressor
EN