Do not clean the shaving foil with a brush.
At regular intervals, put a drop of sewing machine oil onto the foils and
cutter head. Remove excess oil.
, REPLACING THE FOILS AND CUTTERS
To ensure the continued highest quality performance from your shaver, we
recommend that the foil and cutter are replaced every 6 months. These can
be obtained from our nearest Remington® Service Centre
, SIGNS THAT YOUR FOILS AND CUTTERS NEED REPLACING.
Irritation: as foils get worn, you may experience skin irritation.
Pulling: as the cutters wear, your shave may not feel as close and you may feel
the cutter pulling your hair.
Wear through: you may notice that the cutters have worn through the foils.
, TO REPLACE THE FOIL
Ensure the shaver is switched off.
Gently push the small plastic area at either end of the foil. The foil should
then easily detach from the head assembly.
To reassemble, slide the foil into foil bracket and click into position.
Close the head assembly.
, CAUTION
Only hold the plastic to prevent damage to the foil.
Do not press on the foil when replacing.
, REPLACING THE CUTTERS
Ensure the shaver is switched off and open the head assembly (as above).
Grasp the ends of the cutter between your thumb and forefinger and pull
upwards.
To reassemble the cutter, place onto the oscillator tip. Gently push the centre
of the cutter, until it clicks into place.

BATTERY REMOVAL

The battery must be removed from the appliance before it is scrapped.
The appliance must be disconnected from the supply mains when removing
the battery.
Ensure battery is discharged.
Remove the shaver head from the unit.
Using a small screwdriver, remove the screw from the bottom of the shaver.
Pry the front panel from the front housing and remove the switch button.