Connections
The connections are fixed for FA, B and TT and vary for STC, +SA and AUX based on the configuration.
Example 1. Connections with default parameters (Steps 1 = 3, 2 = 2, 9 = 1 of the Functions Table):
CONTROL
UNIT
TERMINALS
SIREN
TERMINALS
Example 2. Connections with balanced inputs with resistance (Steps 1 = 5, 2 = 6, 9 = 1 of the Functions Table):
CONTROL
UNIT
TERMINALS
Gold
Red
Purple
Yellow
SIREN
TERMINALS
Functioning
Alarm: SA input unbalancing activates the Main Sound and the Flash; LED input unbalancing, if programmed with Value 2 or 3,
the Alternative Sound and the Flash is activated (see LED Input in the Functions Table).
Encoding of the alarms: if enabled, it blocks the Sound and the Flash after 5 total balances within 24 hours of SA input and LED
input, if Step 9 = 2 or 3 (refer to Encoding of Alarms and LED Inputs in the Functions Table).
Siren programming
STAND BY
Unbalance the siren Tamper input, the GREEN LED and the RED LED alternately flash with a reduction in brightness, and the STC
and LED inputs are inhibited.
In this phase, the Green and red LEDs luminous intensity can be adjusted, when the PB1 button is briefly pressed, the intensi-
ty of the LEDs increases and when the PB2 button is pressed, the intensity of the LEDs decreases.
ACCESSING PROGRAMMING
from the STAND BY phase, press PB1 or PB2 for at least 3 seconds (GREEN LED, RED LED and FLASH are steady)
as soon as the FLASH turns off, release the button
the first programming step of the 13 possible steps is displayed (1 flash of the RED LED light, followed by "X" flashes of the
GREEN LED)
PROGRAMMING
each time the PB2 button is pressed, a Programming step of the available 13 steps advances sequentially.
• The
Step selected is shown by the flashing of the RED LED (see NUMBER OF RED IMPULSES in the Functions Table)
Examples:
To move from Step 2 to Step 8, press the PB2 button 6 times
To move from Step 11 to Step 6, press the PB2 button 8 times
once the Step to be verified is selected, the Value of the set programming of the 8 possible values is shown by the flashing of
the GREED LED (see NUMBER OF GREEN IMPULSES in the Functions Table).
The displaying is repeated until one of the two buttons PB1 or PB2 is pressed
use the PB1 button to modify the value of the selected step while taking into consideration that every time the button is pushed
the programming sequentially advances one value (see NUMBER OF GREEN IMPULSES in the Functions Table)
Examples:
To move from value 1 to value 4, press the button PB1 3 times
To move from value 6 to value 2, press the button PB1 4 times
the flashing of the green LED (see NUMBER OF GREEN IMPULSES in the Functions Table) indicate the Value selected that
is saved instantly.
EXITING THE PROGRAMMING
Exiting the programming can be done in one of two ways:
balancing the siren Tamper input
keeping the PB2 pressed until the alternate flashing between red and green LEDs
unbalancing the SA input or the LED input, if Step 9 = 2 or 3, without having modified at least one parameter.
In this case, the siren activates its regular alarm cycle.
for Time out after 10 minutes from the last operation
-
If variations of configuration are executed, when exiting the programming it is necessary to unbalance and then rebalance
the SA input or the LED input, if Step 9 = 2 or 3 to restore the correct operation of the siren.
-
The entry and subsequent exiting from programming, reset the Faults, the Alarms Count and the Timers relative to the
Static and Dynamic battery testing. Moreover, during the Programming the Anti-vibration Tamper and the Fault signalling are
inhibited and the signalling of the Over temperature, Anti-foam and +S.A. (if at least one parameter has not been changed)
STC and LED control inputs remain activated.
+ / -: Siren power supply
STC: System status (ON/OFF) signalling input, by closing it on the Negative the Red Status Led
is turned on
+SA: Alarm Control Unit Input, with Positive present the siren does not sound.
LED: Auxiliary signalling input, by closing it on the Negative, the Greed Status Led is turned on
+ / -: Siren power supply
STC: System status (ON/OFF) signalling input, by balancing on the Negative with a 4k7 Ohm
resistance, the Red Status Led is turned on
+SA: Alarm Control Unit Input, with Positive balancing the siren does not sound.
LED: Auxiliary signalling input, by balancing on the Negative with a 4k7 Ohm resistance, the Green
Status Led is turned on
- 13 -