Malfunction
PFC module high
temperature protection
Input power failure
Software control
exception
Current detection circuit
failure
Compressor start failure
Ambient Temperature
device failure on Driver
board
Compressor phase failure
EEPROM data read
malfunction
The inter-chip
communication failure
on the main control
board
Error
code
1. PFC module thermal circuit output
abnormal
EE19
2. Fan motor is abnormal or damaged
3. Fan blade is broken
4. The screw in the driver board is not tight
EE20
The supply voltage fluctuates too much
1. Compressor runs out of step
2. Wrong program
EE21
3. Impurity inside compressor causes the
unstable rotate speed
1. Voltage signal abnormal
EE22
2. Driver board is damaged
3. Main board failure
1. Main board is damaged
2. Compressor wiring error or poor contact or
EE23
unconnected
3. Liquid accumulation inside
4. Wrong phase connection for compressor
EE24
Ambient Temperature device failure
Compressors U, V, W are just connected to
EE25
one phase or two phases.
1. Wrong EEPROM data in the program or
EE27
failed input of EEPROM data
2. Main board failure
EE28
Main board failure
Reason
29
Solution
1. Check the main board or replace the
driver board
2. Check if the motor speed is too low or
fan motor is damaged, replace it by a new
one if any failure.
3. Change the fan blade if it is broken
4. Check the screw on driver board
Check whether the voltage is stable
1. Check the main board or change a new
one
2. Update the correct program
3. Check the refrigeration system
1. Change a new main board
2. Change a new driver board
1. Check the main board or change a new
one
2. Check the compressor wiring according
to the circuit diagram
3. Check the compressor or change a new
one
Change driver board or main board
Check the actual wiring according to the
circuit diagram
1. Re-enter correct EEPROM data
2. Change a new main board
1. Stop electricity supply and restart it
2. Change a new main board