Astralpool Aquasphere VSN Serie Manual De Instrucciones página 32

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 44
VDC voltage too low
protection
Malfunction
Input current over
high protection.
IPM module thermal
circuit is abnormal
IPM module
temperature too high
protection
PFC module
protection
DC fan motor failure
PFC module thermal
circuit is abnormal
3. Compressor liquid and oil
accumulation lead to the current
becomes larger
4.Poor heat dissipation of drive module
or high ambient temperature
5. Compressor or driver board damaged
1. Mother line voltage is too low
EE12
2. Driver board is damaged.
Error
code
1. The compressor current is too
large momentary
2. The water flow is abnormal
EE13
3. Power fluctuations within a short
time
4. Wrong reactor
1. Output abnormity of IPM module
thermal circuit
EE14
2. Fan motor is abnormal or damaged
3. Fan blade is broken
1. Output exception of IPM module
thermal circuit
EE15
2. Fan motor is abnormal or damaged
3. Fan blade is broken
4.The screw on driver board is loose
1. Output exception of PFC module
2. Fan motor is abnormal or damaged
EE16
3. Fan blade is broken
4. Input voltage leap, input power is
abnormal
1. DC motor is damaged
2. For the tri-phase check if the
EE17
neutral is connected
3. Main board is damaged
4. The fan blade is stuck
EE18
The driver board is damaged
Reason
28
2. Check compressor sequence
connection
3. Check the pressure of system by
pressure gauge
4. Check if the ambient and water
temperature is over high
5. If it is the refrigration system failure,
send it to the service center
6. Change driver board
1. Check if the power supply is in the
normal range
2. Change driver board
Solution
1. Check the compressor if it works
normally
2. Check the waterway system
3. Check if the power is in the normal range
4. Check if the reactor is used correctly.
1. Check if the motor speed is too low or
fan motor is damaged, replace it by a new
one.
2. Replace a new driver board
3. Change the fan blade if it is broken
1. Check the main board or replace the
driver board
2. Check if the motor speed is too low or
fan motor is damaged, replace it by a new
one if any failure.
3. Change the fan blade if it is broken
4. Check the screw on driver board
1.Check the main board or replace the
driver board
2. Check if the motor speed is too low or
fan motor is damaged, replace it by a new
one.
3. Change the fan blade
4. Check the input voltage
1. Detect DC motor for mono phase
machine, replace a new one if any failure
2. Check the wiring connection for tri-phase
machine
3. Check the board, replace a new driver
board or main board if any failure
4. Check if there is any barrier in front of
fan blade and remove it
1. Check if the motor speed is too low or
fan motor is damaged, replace it by a new
one.
2. Change a new driver board
Tabla de contenido

Solución de problemas

loading

Tabla de contenido