SAFETY INFORMATION
Please read and understand this entire manual before attempting to assemble, operate or install
the product.

IMPORTANT SAFETY INSTRUCTIONS

WARNING
All electrical connections must be in accordance with local codes and the National Electrical
Code. If you are unfamiliar with methods of installing electrical wiring, secure the services of
a qualified licensed electrician.
Do not install this lighting system in a damp or wet location.
Before turning the light on, make sure the lighting system is clear of all material that could cause a
direct short, and check all electrical connection s to make sure they are tight.
Do not install any part of this system less than 7 ft. above the floor
Lighted lamp is hot! Do not install any lamps closer than 6 in. from any curtain or similar
combustible material.
Disconnect electrical power before adding to o r changing the configuration of the track.
Do not attempt to power anything other than lighting track fixtures on the track.
Do not touch lamp at any time. Turn off power and allow lamps to cool down before replacing.
Do not cut any track sections.
Do not hang or drape anything from the track other than designated track components for this
system.
Ensure groundside of track (exposed copper wire on top of the track rail) is facing the ceiling.
In wall applications, the copper ground should face the wall with the contact channels (inserts
with internal copper wire) facing the ceiling. This system should only be assembled when grounds
are correctly aligned.
Dimmable to 10% with select dimmers: Lutron SCL-153PR-WH, Lutron MACL-153MR-WH, Lutron
TGCL-153PH-WH, LEVITON IPL06-P-LED/LFC, LEVITON 6674-P-LED/LFC.
CAUTION
This track system is to be supplied by a single branch 120-volt, 60-Hertz,15-amp circuit.
To reduce the risk or fire or shock use only with Evolution "LED" track series.
This fixture is intended to be mounted to an outlet junction box. The box must be directly
supported by the building structure.
This track system is not intended for use with a power supply cord or convenience receptacle
adaptor.
This track system is not intended to be supended by a stem or cable.
This equipment has been tested and found to comply with the limits for a Class B digital device,
pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection
against harmful interference in a residential installation. This equipment generates, uses and can
radiate radio frequency energy and, if not installed and used in accordance with the instructions,
may cause harmful interference to radio communications. However, there is no guarantee that
interference will not occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by turning the equipment on
and off, the user isencouraged to try to correct the interference by one or more of the following:
Reorient or relocate the receiving antenna.
Increase the separation between the lighting unit and receiver.
Connect the lighting unit into an outlet on a circuit other than the outlet which the receiver is
connected.
Consult the dealer or an experienced radio/TV technician for assistance.
SAVE THESE INSTRUCTIONS