Failure: poor cooling performance
Possible reason
High ambient temperature
Poor instruction
Poor ventilation
Poor gasket
Poor silicone
Failure: noisy
Possible reason
Dust
Fan broken
Poor heat pump
Failure: frost or ice inside wine cellar
Possible reason
No defrost
Low ambient temperature
9
Hints on Disposal
According to the European waste regulation 2002/96/EC this symbol on the product
or on its packaging indicates that this product may not be treated as household waste.
Instead it should be taken to the appropriate collection point for the recycling of electrical
and electronic equipment. By ensuring this product is disposed of correctly, you will help
prevent potential negative consequences for the environment and human health, which
could otherwise be caused by inappropriate waste handling of this product. For more de-
tailed information about recycling of this product, please contact your local council or your
household waste disposal service.
Declaration of Conformity
Producer: Chal-Tec GmbH, Wallstraße 16, 10179 Berlin, Deutschland.
This product is conform to the following European Directives:
2004/108/EC (EMC)
2011/65/EU (RoHS)
2006/95/EC (LVD)
2009/643/EC (ErP)
Action
The room temperature is hotter than normal
The door is opened too often
Install wine cellar according to our ventilation instruction
Replace a new door gaske
Change the silicone on the surface of the cooling module
Action
Clean the dust from the fan
Change to a new fan
Replace a new heat pump
Action
Stop working for at least one hour, then restart it
Adjust the air-conditioner to be around 25 degree